GuestWorks and DEFINITY ECS Release 9 | Issue 1 |
Technician Handbook for Hospitality Installations | November 2000 |
Installing the System |
|
Connecting the Hospitality Adjuncts | 54 |
|
|
Switch-to-PMS Link
This connection is used to transfer the normal hospitality information, such as names registration,
Parts List
■One digital communications protocol (DCP) port on the switch; the 8400B data module uses a TN2214 or TN2224
■Standard
■One D8W modular cord
■One 8400B data module optioned as shown on page 56, a 7400A DCP data module optioned as shown in Table 5 on Page 57, or a 7400B DCP data module optioned as shown on page 58
■One
■One M25A or M25B cable (or equivalent
Distance Limits
The distance limit when connecting a data module to a TN2214 or TN2224 with 24 AWG wire is 3500 feet (1067 meters). The distance limit when connecting a data module to a TN754C is 5000 feet (1524 meters) with 24 AWG wire, and 4000 feet (1219 meters) with 26 AWG wire.