GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Translations and Testing

 

Switch-to-INTUITY Translations

184

 

 

The following is an example of Page 1 when Mode Code Integration is installed.

add station 720

 

Page

1 of

3

 

 

STATION

 

 

 

Extension:

720

Lock Messages? n

 

BCC: 0

 

Type: VMI

Security Code:

 

TN: 1

 

Port:

01A0201

Coverage Path 1:

 

COR: 35

 

Name: AUDIX1

Coverage Path 2:

 

COS: 4

 

 

 

Hunt-to Station:

Tests? n

 

STATION OPTIONS

Loss Group: 1

Off Premise Station? n

On Page 2:

LWC Reception — Enter audix when using TCP/IP or X.25 signaling. Enter none when using Mode Code integration.

LWC Activation — Enter n when using TCP/IP or X.25 signaling. Enter y when using Mode Code integration.

Switchhook Flash — Enter y.

Distinctive Audible Alerting — Enter n when using Mode Code integration.

Adjunct Supervision — Enter y if Message Manager is not being used; enter n if Message Manager is being used. Enter y when using Mode Code integration whether or not Message Manager is being used.

add station 720

Page 2 of

3

 

STATION

 

 

FEATURE OPTIONS

 

 

 

LWC Reception: audix

 

 

 

LWC Activation? n

Coverage Msg Retrieval?

n

 

CDR Privacy? n

Auto Answer:

none

 

Redirect Notification? n

Data Restriction?

n

 

Per Button Ring Control? n

Call Waiting Indication?

n

 

Bridged Call Alerting? n

Att. Call Waiting Indication?

n

 

Switchhook Flash? y

Distinctive Audible Alerting?

n

 

Ignore Rotary Digits? n

Adjunct Supervision?

y

 

H.320 Conversion? n

 

 

 

 

Per Station CPN - Send Calling Number?

 

 

 

Audible Message Waiting?

n

 

Coverage After Forwarding? s

Page 200