GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Translations and Testing

 

Switch-to-INTUITY Translations

174

 

 

X.25 Signaling

The X.25 PI link requires administration on both the switch and the INTUITY. Only the si and r systems can use an X.25 link. A csi system must use TCP/IP or Mode Code Integration. This section includes procedures for testing the link.

X.25 Link (Switch)

Use the following procedures to administer the link between the switch and the INTUITY for administrative voice messaging. This administration is applicable for si or r systems using a direct IDI connection.

Data Modules on an si System

Use the add data-modulecommand on an si system to administer the data module parameters for a processor interface (PI) link. For this connection, the data modules are integrated into the TN765 PI circuit pack. Set the options as shown, except use the correct extension, COS, and COR as set up for your installation.

add data-module 7991

 

 

Page

1 of

1

 

 

DATA MODULE

 

 

 

Data Extension: 7991

Name: intuity

 

 

 

Type: procr-infc

COS:

15

Maintenance Extension:

7995

Physical Channel:

01

COR:

50

Destination Number:

eia

ITC:

restricted

TN:

 

Establish Connection?

y

Link:

1

DTE/DCE: DTE

Connected Data Module:

DCE

 

 

Enable Link?

n

 

Clocking:

internal

ABBREVIATED DIALING

List1:

SPECIAL DIALING OPTION:

ASSIGNED MEMBERS (Station with a data extension button for this data module)

Ext Name

1:

You must set the Enable Link field to n at this time. After you have set up the processor interface channel, you must go back and enable the link.