GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Installing the System

 

Connecting the Hospitality Adjuncts

39

 

 

Xiox Call Accounting System Link Using

the DCE Port

This connection is used to transfer CDR information to the Xiox call accounting system. This connection is valid for a csi or si system.

Parts List

The DCE port on the switch (this port is found on the Processor Interface Cable of a csi system labeled as J2)

One M25A or M25B cable plus gender changers as needed (or equivalent 25-pin straight-through cable) to connect from the DCE port to the PBX port on the Xiox Intelligent Buffer unit

Xiox Intelligent Buffer unit (includes AC power adapter and cable for connection to the Xiox call accounting PC)

Xiox call accounting PC.

Distance Limits

The distance limit from the switch to the Xiox call accounting PC is 50 feet (15.2 meters). If the distance from the switch and the PC is more than 50 feet (15.2 meters), or if the switch is an r system, see “Switch-to-Call Accounting Link using DCP Data Modules” on page 46.

Page 55