GuestWorks and DEFINITY ECS Release 9 | Issue 1 |
Technician Handbook for Hospitality Installations | November 2000 |
Translations and Testing |
|
172 | |
|
|
The following tests can be run from the INTUITY system to test the link to the switch:
■Customer/Services Administration > Diagnostics > Switch Link Diagnostics > Link Diagnostics
This screen is an example of a TCP/IP link. It shows the link being in service.
+ |
|
|
|
| + | ||
+ |
|
| Link Diagnostics |
|
| + | |
+ |
|
|
|
| + | ||
Switch Link Type: LAN |
|
| Country: UNITED STATES | ||||
|
|
|
| Switch: DEFINITY OVERLAN | |||
|
|
|
|
|
| ||
|
|
|
|
|
| ||
Switch | Link | Session | Switch | Link | Session | ||
Number | Status | Status | Number | Status | Status | ||
1 | UP | UP |
|
|
| ||
|
|
|
|
|
| ||
+ |
|
|
|
| + |
If the link status and session status show DOWN, use the following function keys to test the link:
—F3tests to see if the link is electrically connected. Run this test first. If it fails, check the cabling.
— | resets the link. After finished, press | to refresh the link. If it still |
| F2 | F5 |
does not come up, check the switch and INTUITY system adminis- tration.
You can also press F8 to change the function key labels and use the following to control the status of the link:
—
—F3releases the link from
■Customer/Services Administration > Diagnostics > Switch Link Diagnostics > Session Layer Diagnostics
+ |
|
|
|
|
| + | ||
+ |
|
|
| Session Layer |
|
| + | |
+ |
|
|
|
|
| + | ||
Switch Link Type: LAN |
| Country: UNITED STATES | ||||||
|
|
|
| Switch: DEFINITY OVERLAN | ||||
|
|
|
|
|
|
| ||
|
| Transmit | Receive |
|
| Transmit | Receive | |
Switch | Session | Sequence | Sequence | Switch | Session | Sequence | Sequence | |
Number | State | Number | Number | Number | State | Number | Number | |
1 | DATA | 148 | 45 |
|
|
| ||
|
|
|
|
|
|
| ||
+ |
|
|
|
|
| + |
Press F5 every few seconds to see if the sequence numbers increment. If the numbers do not increment, data transfer is not taking place.