GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Installing the System

 

Connecting the Hospitality Adjuncts

58

 

 

7400B Options

The options on the 7400B must be set using an ASCII data terminal or a PC using a terminal emulation package. You must connect the data terminal or PC to the EIA interface connector on the back of the 7400B. For the switch-to-PMS link, only a subset of options must be changed. These options are changed using the AT command set. Use the following steps to set the options on the 7400B:

1.Set the option dip switches SW1-1 to ON (without phone), SW1-5 to OFF, and SW1-8 to OFF.

2.Set the speed on the data terminal or terminal emulation package to match the speed of the PMS. By doing this, the speed on the 7400B will autobaud to match the correct speed.

3. From the data terminal or PC, type at Enter . This automatically sets the speed and parity for the connection. The OK prompt should display.

4.Type the following commands as shown. (The character 0 is the number

 

zero.) Before you press

 

Enter for each command, make sure that the

 

command has been entered correctly. The e0 option on the last command

 

turns off keyboard echo, which means that after you enter this command,

 

any future keyboard entries will not be displayed, and the OK prompt is not

 

displayed.

 

 

 

 

 

 

 

at&f

Enter (the

OK prompt displays)

 

 

at&c1&d2&s1s0=1

Enter

(the

OK prompt displays)

 

ate0q1&w0&y0&v

Enter

 

 

 

 

 

The &v portion of the last command displays the current set of options.

 

Your screen should look something like this:

ACTIVE PROFILE:

 

 

 

 

 

 

 

 

B1 E0 L2 M1 Q1 V1

X4 Y0 &C1 &D2 &G0 &J0 &L0 &P0 &Q0 &R0 &S1 &X0 &Y0

S00:001

S01:000

S02:043 S03:013

S04:010

S05:008

S06:002

S07:060

S08:002 S09:006 S10:014 S12:050 S14:AAH S16:00H S18:000 S21:00H

S22:76H S23:0BH S25:005 S26:001 S27:40H

 

 

 

 

STORED PROFILE 0:

 

 

 

 

 

 

 

B1 E0 L2 M1 Q1 V1

X1 Y0 &C1 &D2 &G0 &J0 &L0 &P0 &Q0 &R0 &S1 &X0

S00:001 S14:AAH S18:000 S21:00H S22:76H S23:0BH S25:005 S26:001

S27:40H

 

 

 

 

 

 

 

 

 

STORED PROFILE 1:

 

 

 

 

 

 

 

B1 E1 L2 M1 Q0 V1

X4 Y0 &C0 &D0 &G0 &J0 &L0 &P0 &Q0 &R0 &S0 &X0

S00:000 S14:AAH S18:000 S21:00H S22:76H S23:1BH S25:005 S26:001

S27:40H

TELEPHONE NUMBERS:

5.Disconnect the data terminal or PC from the 7400B.

6.Reconnect the unit as shown in Figure 18.

If your PMS requires a different set of options, consult the 7400B Data Module

User’s Guide.

Page 74
Image 74
Avaya 555-231-743 manual User’s Guide