Translations and Testing

 

Printer Translations (Switch)

232

 

 

The following will display if the printer is turned off; turn on the printer power.

TD dark

red RD*

RTS dark

red CTS*

DSR* red

dark DTR

CD* red

NOTE:

RTS will be lit on the front panel of the 7400A or 7400B. The CTS lead shows green when used with an 8400B.

The following will display if the printer is off-line; press the on-line button on the printer.

TD red

red RD*

RTS red

green CTS*

DSR* green

green DTR

CD* green

Another way to test the log printer connection is to create an Automatic Wakeup call for the test room. If the printer is working, an Automatic Wakeup call request message prints on the log printer.