GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Translations and Testing

 

Switch-to-PMS Link Translations

213

 

 

Data Modules

Use the add data-modulecommand to administer the data module connected between the switch and the PMS.

add data-module 7899

 

 

DATA MODULE

 

 

Data Extension:

7899

Name: PMS LINK

BCC:

2

Type:

pdm

COS:

1

Remote Loop-Around Test?

n

Port:

01B0102

COR:

50

Secondary data module?

n

ITC:

restricted

TN:

1

Connected to:

dte

ABBREVIATED DIALING

List1:

SPECIAL DIALING OPTION:

ASSIGNED MEMBER ( Station with a data extension button for this data module )

Ext Name

1:

Housekeeping Status

Use the change feature-access-codescommand to assign the housekeeping status feature access codes. Administer only the feature access codes that the vendor supports and that match the status definitions.

change feature-access-codesPage 5 of 5

FEATURE ACCESS CODE (FAC)

Hospitality Features

Automatic Wakeup Call Access Code: *98

Housekeeping Status (Client Room) Access Code: *81

Housekeeping Status (Client Room) Access Code: *82

Housekeeping Status (Client Room) Access Code: *83

Housekeeping Status (Client Room) Access Code: *84

Housekeeping Status (Client Room) Access Code:

Housekeeping Status (Client Room) Access Code:

Housekeeping Status (Station) Access Code:

Housekeeping Status (Station) Access Code:

Housekeeping Status (Station) Access Code:

Housekeeping Status (Station) Access Code:

Verify Wakeup Announcement Access Code: *89

Voice Do Not Disturb Access Code: *33

Page 229
Image 229
Avaya 555-231-743 manual Data Modules, Housekeeping Status