GuestWorks and DEFINITY ECS Release 9 | Issue 1 |
Technician Handbook for Hospitality Installations | November 2000 |
Translations and Testing |
|
Miscellaneous Translations | 98 |
|
|
Class of Service (INTUITY)
Use the following screens to administer the INTUITY COS for the guest rooms and the office staff INTUITY AUDIX subscribers. To access the INTUITY COS screens, use the AUDIX Administration > change cos command. On Page 1, the Type field must be set to
change cos 0 |
| Page 1 of 2 |
| CLASS OF SERVICE |
|
Name: class00 | COS Number: 0 | Modified? y |
Addressing Format: extension |
|
|
| Login Announcement Set: System | |
System Multilingual is ON | Call Answer Primary Annc. Set: System | |
Call Answer Language Choice? n Call Answer Secondary Annc. Set: System | ||
PERMISSIONS |
|
|
Type: | Announcement Control? y | Outcalling? n |
Priority Messages? n | Broadcast: none | IMAPI Access? y |
IMAPI Message Transfer? n | Fax Creation? n | Trusted Server Access? y |
If Fax Creation was y on Page 1, change the following on Page 2:
■ Voice Mail Message, Maximum Length — Enter 1200.
■ Call Answer Message, Maximum Length — Enter 1200.
■Mailbox Size, Maximum — Enter 4800.
change cos 0 |
|
|
|
|
|
| Page 2 of 2 |
|
| CLASS OF SERVICE |
|
|
| ||
INCOMING MAILBOX | Order: fifo |
|
| Category Order: nuo | |||
Retention Times (days), | New: | 10 | Old: | 10 | Unopened: | 10 | |
OUTGOING MAILBOX | Order: | fifo |
|
| Category Order: | unfda | |
Retention Times(days),File Cab: | 10 | Delivered/Nondeliverable: | 5 | ||||
Voice Mail Message (seconds), | Maximum Length: | 300 | Minimum Needed: | 32 | |||
Call Answer Message (seconds), | Maximum Length: | 120 | Minimum Needed: | 8 | |||
End of Message Warning | Time (seconds): |
|
|
| |||
Maximum Mailing Lists: | 25 | Total Entries in all Lists: | 250 | ||||
Mailbox Size (seconds), Maximum: | 1200 |
| Minimum Guarantee: | 0 |