182Switch-to-INTUITY Translations

Use the change system-parameters mode-code command to verify that the

default mode code parameters are correct for this installation.

Mode Code Integration (INTUITY)

Mode Code Integration on the INTUITY is described in the following documents :

INTUITY Messaging Solutions Release 4 MAP/5P System Installation

INTUITY Messaging Solutions Integration with System 75, DEFINITY

Generics 1 & 3, and R5/6

INTUITY Messaging Solutions Release 5 Documentation (CD).

Continue with “INTUITY AUDIX Voice Ports (Switch)” on page 183.

change system-parameters mode-code Page 1 of 1
MODE CODE RELATED SYSTEM PARAMETERS
MODE CODES (FROM SWITCH TO VMS)
Direct Inside Access: #00
Direct Dial Access - Trunk: #01
Internal Coverage: #02
External Coverage: #03
Refresh MW Lamp: #06
System In Day Service: #11
System In Night Service: #12
OTHER RELATED PARAMETERS
DTMF Duration - On (msec): 100 Off (msec): 100 Sending Delay (msec):100
VMS Hunt Group Extension: