GuestWorks and DEFINITY ECS Release 9 | Issue 1 |
Technician Handbook for Hospitality Installations | November 2000 |
Installing the System |
|
Connecting the Hospitality Adjuncts | 24 |
|
|
Switch-to-INTUITY Admin Link (Mode Code
Integration)
When using Mode Code Integration, the administrative link between the switch and the MAP (the link that transfers information to support the INTUITY AUDIX service for office staff voice messaging) connects by way of an analog port on the switch and a voice port on the MAP. This connection is the same as the voice port connections shown in
In other words, the voice ports used for leaving and retrieving messages on the INTUITY system are the same voice ports used for Mode Code Integration. This means that the ports will be in use for the amount of time it takes to leave a message, plus the amount of time it takes for the Mode Codes to exchange messages between the switch and INTUITY. This will affect the
Mode Code Integration should not be used if TCP/IP or X.25 link integration is available. See
NOTE:
When using Mode Code Integration, you cannot take advantage of the Switch/INTUITY/PMS Link Integration feature. This means that you must install the link shown in “INTUITY
Mode Code Integration between the switch and the MAP is described in more detail in the following documents:
■DEFINITY ECS Administrator’s Guide
■INTUITY Messaging Solutions Release 4 MAP/5P System Installation
■INTUITY Messaging Solutions Integration with System 75, DEFINITY Generics 1 & 3, and R5/6
■INTUITY Messaging Solutions Release 5 Documentation (CD).