GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743 Issue 1
November 2000
Translations and Testing

99Miscellaneous Translations

System Parameters (INTUITY)

Use the AUDIX Administration > change system-parameters features

command to assign the INTUITY system parameters. The parameters will vary

according to the customer’s needs. See

INTUITY Messaging Solutions
Administration

for more information about other options on these screens.

change system-parameters features Page 1 of 4
SYSTEM-PARAMETERS FEATURES
LOG-IN PARAMETERS
Login Retries: 3 Consecutive Invalid Attempts: 18
System Guest Password: Minimum Password Length: 6
SUBSCRIBER PASSWORD AGING LIMITS (DAYS)
Password Expiration Interval: 0 (0 for no password aging)
Minimum Age Before Changes: 0
Expiration Warning: 0 (0 for no warning)
INPUT TIME LIMITS (SECONDS)
Normal: 60 Full Mailbox Timeout: 5 Wait (*W): 180
Between Digits at Auto-attendent or Standalone Menu: 3 (3-12)
DISCONNECT OPTIONS
Quick Silence Disconnect? n Silence Limit? 30 (5-30 seconds)
change system-parameters features Page 2 of 4
SYSTEM-PARAMETERS FEATURES
MISCELLANEOUS PARAMETETERS
Broadcast Mailbox Extension:
System Prime Time, Start: 08:00 End: 17:00d Length: 6
Increment(l/s), Rewind: s Advance: s
FEATURE ACTIVATIONTraffic Collection? y
Name Record by Subscriber? y
Multiple Personal Greetings? y
End of Message Warning? y Warning Time (seconds): 15
Priority on Call Answer? n
Call Answer Disable? n
Address Before Record? n
MULTIMEDIA PARAMETERS
Fax Print Destination Prefix:
Text to Speech Conversion: none