GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Translations and Testing

 

INTUITY Lodging-to-PMS Translations

201

 

 

Testing the INTUITY Lodging-to-PMS Link

After the connection is complete, and the link is active, the mini-tester should show the following results (see the Note on page 5). The leads marked with an asterisk are controlled by the INTUITY system, and the PMS controls the other leads.

!CAUTION:

After using a mini-tester to check data leads, you MUST remove the mini-tester from the connection. DO NOT leave the mini-tester in-line during actual operation.

TD* red

red RD

RTS* dark

green CTS

DSR green

green DTR*

CD green

After the connection is complete and the INTUITY link is active, the following may indicate that the PMS is not active. Check with the vendor to verify whether the link is active.

TD* red

red RD

RTS* dark

red CTS

DSR red

green DTR*

CD red

Page 217
Image 217
Avaya 555-231-743 manual Testing the Intuity Lodging-to-PMS Link