H3 Control Testing (Model MGR6775AA*)

Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

H3 Control Testing (Model MGR6775AA*)

H3 Controlled

Oven

Press Upper Bake pad.

While increasing or decreasing oven

Model MGR6775AD*

temperature

Enter 550 on the digit-pad.

temperature, this does not affect self-

 

adjustment

Immediately press and hold Upper Bake

cleaning temperature.

 

(Upper Oven)

pad for 3 seconds.

 

 

 

Adjust oven from -35° to +35° (-37.2° to +

 

 

 

1.6° C) in 5° F (2.7° C) increments by

 

 

 

pressing More+ or Less-pads. To avoid

 

 

 

over adjusting the oven, move temperature

 

 

 

5° F (2.7° C) each time. Wait 4 seconds

 

 

 

for the data entry timer to expire to accept

 

 

 

the change. Temperature adjustment is

 

 

 

retained even through a power failure.

 

H3 Controlled

Oven

Press Lower Bake pad.

While increasing or decreasing oven

Model MGR6775AD*

temperature

Enter 550 on the digit-pad.

temperature, this does not affect self-

 

adjustment

Immediately press and hold Lower Bake

cleaning temperature.

 

(Lower Oven)

pad for 3 seconds.

 

 

 

Adjust oven from -35° to +35° (-37.2° to +

 

 

 

1.6° C) in 5° F (2.7° C) increments by

 

 

 

pressing More+ or Less-pads. To avoid

 

 

 

over adjusting the oven, move temperature

 

 

 

5° F (2.7° C) each time. Wait 4 seconds

 

 

 

for the data entry timer to expire to accept

 

 

 

the change. Temperature adjustment is

 

 

 

retained even through a power failure.

 

H3 Controlled

Temperature

Press and hold Upper Cancel and Upper

This mode enables the user to indicate

Model MGR6775AD*

display

Bake pads for 3 seconds.

°F or °C on the display.

H3 Controlled

Factory Default

Press and hold Upper Cancel and Warm

Allows the clock to be reset to factory

Model MGR6775AD*

 

pads for 3 seconds.

settings.

H3 Controlled

Clock Display

Press and hold Upper Cancel and Clock

Allows clock to be toggled On or OFF.

Model MGR6775AD*

 

pads for 3 seconds.

 

H3 Controlled

24 Hour Clock

Press and hold Upper Cancel and Delay

Allows the time on the clock to be

Model MGR6775AD*

 

pads for 3 seconds.

toggled from 12 hour or 24 hour display.

H3 Controlled

Demo

Press and hold Upper Cancel and Less -

Enters a demonstrative sales mode.

Model MGR6775AD*

 

pads for 3 seconds.

 

H3 Controlled

Twelve hour off

Control will automatically cancel any

See Sabbath mode to disable.

Model MGR6775AD*

 

cooking operation and remove all relay

 

 

 

drives 12 hours after the last pad touch.

 

H3 Controlled

Sabbath Mode

Hold Clock pad for 5 seconds to activate

“SAb” displays and flashes for 5

Model MGR6775AD*

 

Sabbath mode.

seconds.

 

 

Hold Clock pad for 5 seconds to disable

All pad inputs are disabled except for

 

 

Sabbath mode.

CANCEL and CLOCK pads.

 

 

Oven must be in BAKE mode before

This mode disables the normal 12 hour

 

 

enabling SABBATH.

shutoff to allow operation of the bake

 

 

 

mode for a maximum of 72 hours.

H3 Controlled

Beeper Volume

Hold Upper Cancel and More+ pads for 3

Volume settings are Low, Medium and

Model MGR6775AD*

 

seconds to adjust beeper loudness level.

High.

H3 Controlled

Child lock out

Press and hold Upper Cancel and Cook &

This is a safety feature that can be used

Model MGR6775AD*

 

Hold pads for 3 seconds. “OFF” will

to prevent children from accidentally

 

 

display where the temperature normally

programming the oven. It disables the

 

 

appears. “LOCK” will display flashing while

electronic oven control.

 

 

door is locking.

Child lockout features must be reset after

 

 

To reactivate the control, press and hold

 

 

Cancel and Cook & Hold pads for 3

a power failure.

 

 

seconds.

 

H3 Controlled

Diagnostic

Press and hold Upper Cancel and Timer

The last 5 diagnostic codes will be stored

Model MGR6775AD*

Code Display

for 3 seconds within 5 minutes of power up.

in the non-volatile memory.

 

 

See “Quick Test Mode.”

See “Description of Error Codes” for

 

 

Cycle through the codes.

 

 

 

explanation.