!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Component Troubleshooting

Problem

Possible Cause

Correction

 

Poor ground on burner cap

Clean burner cap.

Burners will not ignite; no

Weak or failed spark module

Replace spark module.

spark at top burner.

Low gas pressure

Verify pressure 4” WCP for

 

 

natural, 10” WCP for LP.

 

No 120 VAC to range

Verify voltage at wall outlet.

 

Micro switch contacts not closing

Check wiring against appropriate

 

 

wiring diagram. Verify all

 

 

terminals and connections are

 

Faulty wiring. Bad connection at burner

correct and tight. Check micro

Burner will not ignite. No

switch contacts.

electrode and electrode socket

Check wiring against appropriate

spark to burner ignitors when

 

wiring diagram. Verify all

burner knob is rotated to

 

 

terminals and connections are

“LITE” position.

 

 

correct and tight.

 

Inoperative spark module

 

Check module according to

 

Electrode dirty. Burner cap dirty

testing procedures information.

 

Clean electrode or burner cap.

 

Cracked or broken electrode, electrode

 

 

 

wire or electrode socket

Replace electrode.

 

Check for cracked ignitor or pinched ignitor

 

 

wire

Replace ignitor lead or electrode.

 

Poor continuity to burner cap

Clean burner cap and lead.

No spark or only random

Bad ground connection or lack of continuity

 

to ground or ignitor

Tighten ground connection and

spark at one ignitor.

 

correct any breaks in ground path

 

 

 

 

from ignitor path to unit ground

 

Cracked or broken ignitor extension lead....

path.

 

Replace ignitor lead.

 

Shorted valve switch/harness

Replace switch/harness. If

 

 

shorting is caused by excessive

Unit continues to spark after

 

spillovers, customer education is

 

advised.

knob is turned to OFF

 

Switch has slipped off the valve

Carefully reposition switch on

position.

 

valve and rotate from OFF to

 

 

 

 

high, several times to verify

 

 

switch is not broken.

 

No voltage to control

Check for 120 VAC at control. If

 

 

no voltage check power source.

No oven operation in bake or

No voltage from control

Check 120 VAC to ignitor, if no

broil.

Loose wire connection or broken wire

voltage, replace control.

 

Verify all connections are clean

 

 

and tight, replace broken wire.

14

16023415

©2004 Maytag Services

Page 14
Image 14