Maytag MGR6875ADB/Q/S/W manual “Quick Test” Mode for Electronic Range Control, Testing Procedures

Models: MGR6775ADB/Q/S/W MGR6875ADB/Q/S/W

1 69
Download 69 pages 28.57 Kb
Page 22
Image 22
“Quick Test” Mode for Electronic Range Control

Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

“Quick Test” Mode for Electronic Range Control

Follow the procedure below to perform the Electronic Range Control (ERC) quick test. Instructions must be entered within 32 seconds of each other (via the touch pad) or the ERC will exit the quick test.

1.Press and hold the UPPER CANCEL and BROIL pads for 3 seconds.

2.Once the control has entered the “Quick Test” mode, release both pads.

3.Press each of the following pads indicated in the table below.

NOTE: Press the applicable pad once to activate the associated response.

Press the applicable pad a second time to deactivate the associated response.

Display will indicate the following:

Pad

Response

 

BAKE

Bake DLB and Bake relay activated

BROIL

Broil DLB and Broil relay activated

KEEP WARM

Bake DLB and Broil DLB activated

CONVECT BAKE

Convection Fan on low speed

CONVECT ROAST

Convection Fan on high speed

CLEAN

MDL relay activated

COOK & HOLD

Displays last diagnostic code

FAVORITE

Displays EEPROM version number

TIMER

Displays main code version number

CLOCK

All display segments illuminated

OVEN LIGHT

Oven light activated

CANCEL

Exit Quick Test mode

1

Even segments on

2

Odd segments on

3

Convection Ring activated; Convection Ring DLB activated

4

N/A

5

N/A

6

N/A

7

N/A

8

N/A

9

N/A

AUTOSET

Steps through last 5 diagnostic codes

Setup Options (0) pad is pressed “Press Desired Pad for Selection” will scroll in the display. When a feature is displayed the AUTO SET pad is used to toggle the options. Use the chart below to identify the available options.

Control

Pad

Default Option
Additional Options
Function

Selection

 

 

12 hour shut-off

1

12 HR Energy Saver ON

12 HR Energy Saver OFF

Timer beeps

2

Timer Reminder Beeps for 5 Min.

Timer Reminder Beeps for 30 Min.

 

 

 

No Timer Reminder Beeps

Cook time beeps

3

Cook Time Reminder Beeps for 30 Min.

Cook Time Reminder Beeps for 5 Min.

 

 

 

No Cook Time Reminder Beeps

Control lock

4

Control Unlocked

Control Locked

Scroll speed

5

Medium Speed

Fast Speed Slow Speed

Volume level

6

6 bars

1 to 8 bars

Temp C/F

7

Degrees F

Degrees C

Language

8

English

French, Spanish

Default

9

Press AUTO SET for Factory Settings

N/A

Display On/Off

Clock

Clock Display is ON

Clock Display is OFF

22

 

16023415

©2004 Maytag Services

Page 22
Image 22
Maytag MGR6875ADB/Q/S/W “Quick Test” Mode for Electronic Range Control, Display will indicate the following, Response