Maytag MGR6775ADB/Q/S/W manual Troubleshooting Procedures, Possible Cause, No gas flows to burner

Models: MGR6775ADB/Q/S/W MGR6875ADB/Q/S/W

1 69
Download 69 pages 28.57 Kb
Page 15
Image 15
No gas flows to burner.

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Problem

Possible Cause

 

Failed ignitor

 

Gas pressure too high

No gas flows to burner.

 

Ignitor glows red.

 

 

Failed gas valve

 

Loose wire connection or broken wire

 

 

 

Ignitor positioned too far from burner

 

Dirt or grease in orifice or burner

 

Insufficient gas pressure

Gas flows to bake/broil

 

burner, but burner does not

 

light.

Power outage

 

Power outage ..............................................

Broil burner shuts off shortly after the start of self-clean operation. Bake and broil

functions operate normally.

Control Error ................................................

No power to fan motor.................................

Fan motor does not operate.

Failed fan motor or winding/frozen shaft .....

Correction

Check ignitor current draw, 3.2 – 3.6 Amps. Replace ignitor, if it fails test.

Check for correct gas pressure. Natural gas pressure should be 4" WCP and LP gas pressure should be 10" WCP.

Check gas valve for continuity.

Verify all connections are clean and tight, replace broken wire.

Reposition ignitor closer to bake/broil burner.

Clean orifice or burner.

Check for correct gas pressure. Natural gas pressure should be 5" WCP and LP gas pressure should be 10" WCP.

Verify power is present at unit. Verify that the circuit breaker is not tripped.

Replace household fuse, but do not fuse capacity.

Verify power is present at unit. Verify that the circuit breaker is not tripped.

Replace household fuse, but do not fuse capacity.

See “Control Systems Troubleshooting.”

Check for 120 VAC supplied at fan motor. If no voltage is present, check for broken or loose wiring between fan motor and relay board. If voltage is present at fan motor, go to the next step.

Check motor winding for continuity. Check for a frozen motor shaft. Check for broken wiring between motor and neutral terminal block.