Maytag MGR6875ADB/Q/S/W manual Oven Door Hinge, Regulator, Gas Valve, Door Plunger, Spark Module

Models: MGR6775ADB/Q/S/W MGR6875ADB/Q/S/W

1 69
Download 69 pages 28.57 Kb
Page 28
Image 28

Disassembly Procedures

!WARNING

To avoid risk of electrical shock, personal injury, or death: disconnect electrical and gas supply before servicing.

Oven Door Hinge

NOTE: Removal of range from installation position is required.

1.Disconnect power before servicing.

2.Remove oven door, see "Oven Door(s)-Door Removal" procedure.

3.Remove maintop, see "Maintop Removal" procedure. (Perform steps 1 – 6.)

4.Remove appropriate side panel (left or right), see "Side Panel" procedure.

5.Remove screws securing hinge to front frame flange.

6.Complete hinge assembly may be removed.

7.Reverse procedure to reassemble.

NOTE: The door hinges are colored coded for ease of installation. The upper spring hook is gold and the lower spring hook is white.

Regulator

NOTE: Removal of range from installation position is required.

1.Disconnect power before servicing.

2.Slide range forward out of installation position to gain access to components.

3.Disconnect tubing from regulator.

4.Remove screws securing bracket to back of unit.

5.Remove screws securing regulator to support bracket.

6.Reverse procedures to reassemble.

NOTE: When reconnecting supply line to regulator use pipe dope compound to seal the connection.

NOTE: Perform gas leak test.

Gas Valve

NOTE: Removal of range from installation position is required.

1.Disconnect power before servicing.

2.Remove range from installation position, see "Move and/or Replacing Range" procedure.

3.Remove screws securing bottom rear access panel to chassis.

4.Remove screws securing top rear access panel to chassis.

5.Disconnect tubing from gas valve.

6.Disconnect and label wire terminals from gas valve.

7.Remove screws securing gas valve to chassis.

8.Reverse procedures to reassemble.

NOTE: Perform gas leak test.

Door Plunger

NOTE: Removal of range from installation position is required.

1.Disconnect power before servicing.

2.Remove range from installation position, see "Move and/or Replacing Range" procedure.

3.Remove maintop, see "Maintop Removal" procedure. (Perform steps 1 – 6.)

4.Remove right side panel, see "Side Panel" procedure.

5.Disconnect and label wire terminals from door plunger switch.

6.Open oven door and remove screws securing door plunger to the front of the oven cavity.

7.Reverse procedures to reassemble.

Spark Module

NOTE: Removal of range from installation position is required.

1.Disconnect power before servicing.

2.Remove range from installation position, see "Move and/or Replacing Range" procedure.

3.Remove screws securing bottom rear access panel to chassis.

4.Remove screws securing top rear access panel to chassis.

5.Label and disconnect wire terminals from spark module.

6.Remove spark module from secured position.

7.Reverse procedures to reassemble.

Convection Assembly

(Model MGR6875AD*)

1.Disconnect power before servicing.

2.Remove oven door, see "Oven Door(s)-Door Removal" procedure.

3.Remove oven racks from oven cavity.

4.From inside the oven cavity (center-rear), remove screws securing assembly shroud or ring-cover.

5.Remove screws securing assembly to cavity.

6.Remove by gently rotating assembly until enough clearance is established between assembly, cavity wall and wire terminals/connectors.

7.Disconnect and label wire terminals from heat element and assembly (connector block).

8.Remove assembly from cavity.

9.Reverse procedures to reassemble.

28

16023415

©2004 Maytag Services

Page 28
Image 28
Maytag MGR6875ADB/Q/S/W manual Oven Door Hinge, Regulator, Gas Valve, Door Plunger, Spark Module, Convection Assembly