Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.
H2 Control Testing (Model MGR6875AA*)
H2 Controlled | Oven temperature | Press Upper Bake pad. | While increasing or decreasing oven |
Model MGR6875AD* | adjustment | Enter 550 on the | temperature, this does not affect self- |
| (Upper Oven) | Immediately press and hold Upper Bake | cleaning temperature. |
|
| pad for 3 seconds. |
|
|
| Adjust oven from |
|
|
| + 1.6° C) in 5° F (2.7° C) increments by |
|
|
| pressing Autoset pad. To avoid over |
|
|
| adjusting the oven, move temperature 5° |
|
|
| F (2.7° C) each time. Wait 4 seconds for |
|
|
| the data entry timer to expire to accept |
|
|
| the change. Temperature adjustment is |
|
|
| retained even through a power failure. |
|
H2 Controlled | Oven temperature | Press Lower Bake pad. | While increasing or decreasing oven |
Model MGR6875AD* | adjustment | Enter 550 on the | temperature, this does not affect self- |
| (Lower Oven) | Immediately press and hold Lower Bake | cleaning temperature. |
|
| pad for 3 seconds. |
|
|
| Adjust oven from |
|
|
| + 1.6° C) in 5° F (2.7° C) increments by |
|
|
| pressing Autoset pad. To avoid over |
|
|
| adjusting the oven, move temperature 5° |
|
|
| F (2.7° C) each time. Wait 4 seconds for |
|
|
| the data entry timer to expire to accept |
|
|
| the change. Temperature adjustment is |
|
|
| retained even through a power failure. |
|
H2 Controlled | Temperature | Press and hold Upper Cancel and | This mode enables the user to indicate |
Model MGR6875AD* | display | Upper Bake pads for 3 seconds. | °F or °C on the display. |
H2 Controlled | Clock Display | Press and hold Upper Cancel and | Allows clock to be toggled On or OFF. |
Model MGR6875AD* |
| Clock pads for 3 seconds. |
|
H2 Controlled | 24 Hour Clock | Press and hold Upper Cancel and | Allows the time on the clock to be |
Model MGR6875AD* |
| Favorite pads for 3 seconds. | toggled from 12 hour or 24 hour display. |
H2 Controlled | Factory Default | Press and hold Upper Cancel and | Allows the clock to be reset to factory |
Model MGR6875AD* |
| Upper Keep Warm pads for 3 seconds. | settings. |
H2 Controlled | Twelve hour off | Control will automatically cancel any | See Sabbath mode to disable. |
Model MGR6875AD* |
| cooking operation and remove all relay |
|
|
| drives 12 hours after the last pad touch. |
|
H2 Controlled | Sabbath Mode | Hold Clock pad for 3 to 5 seconds to | “SAbbAth” will display for 5 seconds, |
Model MGR6875AD* |
| activate Sabbath mode. | then change to “SAb” (displayed in Temp |
|
|
| area). |
|
| Hold Clock pad for 3 to 5 seconds to | All pad inputs are disabled except for |
|
| disable Sabbath mode. | CANCEL and CLOCK pads. |
|
|
| This mode disables the normal 12 hour |
|
|
| shutoff to allow operation of the bake |
|
|
| mode for a maximum of 72 hours. |
H2 Controlled | Beeper Volume | Hold Upper Cancel and Delay pads for | Volume settings are Low, Medium and |
Model MGR6875AD* |
| 3 seconds to adjust beeper loudness. | High. |
H2 Controlled | Child lock out | Press and hold Upper Cancel and Cook | This is a safety feature that can be used |
Model MGR6875AD* |
| & Hold pads for 3 seconds. “OFF” will | to prevent children from accidentally |
|
| display where the temperature normally | programming the oven. It disables the |
|
| appears. “LOCK” will display flashing | electronic oven control. |
|
| while door is locking. | Child lockout features must be reset after |
|
| To reactivate the control, press and hold | |
|
| Cancel and Cook & Hold for 3 seconds. | a power failure. |
H2 Controlled | Diagnostic Code | Press and hold Upper Cancel and | The last 5 diagnostic codes will be stored |
Model MGR6875AD* | Display | Autoset pads for 3 seconds. | in the |
|
| See “Quick Test Mode.” | See “Description of Error Codes” for |
|
| Cycle through the codes using the | |
|
| number pads 1 through 5. | explanation. |
20 | 16023415 | ©2004 Maytag Services |