Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

!CAUTION

Verify proper grounding before checking for trouble.

Be careful of the high voltage circuit.

Discharge the high voltage capacitor.

When checking the continuity of the switches or of the high voltage transformer, disconnect one lead wire from these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.

Do not touch any part of the circuit on the printed circuit board, since static electric discharge may damage the control panel. Always touch yourself to ground while working on this panel to discharge any static charge built up on your body.

Control Systems Troubleshooting

Description of Error Codes

The Diagnostic Code Display Mode allows viewing of the error diagnostic codes.

Each error code consists of four digits. The following table describes the function of each digit.

Digit

1st

2nd

3rd

4th

 

 

Description

Primary System:

1 – Local to the control circuit board

 

3

– Sensor or meat probe

 

4

– Control input

 

9

– Door lock

Measurable:

d – Diagnostic: measurable parameter

 

c – Control related, replace control

Secondary System: Sequential numbering

Oven Cavity:

1 – Upper oven (or single cavity oven)

 

2

– Lower oven

 

c – Control specific

Diagnostic Code Display Mode may be activated by pressing and holding the AUTOSET pad for 3 seconds at power-up. Diagnostic Code Display Mode may be entered only when applying power to the control.