Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Illustration

Component

Test Procedure

Results

 

Triple thermal valve

Disconnect wiring to valve.

 

 

 

Measure resistance on upper and

 

 

 

lower bake circuit

Continuity, If not replace.

 

 

Measure resistance on broil circuit

Continuity, If not replace.

 

 

 

! WARNING

 

 

 

Do not attempt to open valve with

 

 

 

 

120 VAC.

 

 

 

 

 

 

Pressure regulator

Verify gas pressure (W.C.P.).

5" Natural

 

 

 

If on LP service verify proper gas

10" LP/propane

 

 

 

 

 

supply conversion.

 

 

 

 

 

 

 

 

Shut off valve

Check to verify gas supply is turned

Gas ON ....

slot at 9 o’clock position

 

on.

Gas OFF...

slot at 12 o’clock position

 

Located on surface valve manifold

 

 

 

 

near maintop upsweep.

 

 

 

 

 

 

 

 

Convection Assembly

Measure voltage

120 VAC.

 

 

Convection Element

Remove wires, check resistance

Approximately 28 to 33 .

Convection Motor

Check motor windings to ground

No continuity.

 

 

Approx. 900 RPM.

Model MGR6875AD*

 

 

 

 

Power cord 3-wire

Verify resistance of wires to

Continuity

 

 

 

terminals.

 

 

 

18

16023415

©2004 Maytag Services

Page 18
Image 18
Maytag MGR6875ADB/Q/S/W, MGR6775ADB/Q/S/W manual Testing Procedures