Chapter 6. Troubleshooting

This chapter provides some hints to common problems seen while installing or using ParaStation5. Of course, more help will be provided by <support@par-tec.com>.

6.1. Problem: psiadmin returns error

When starting up the ParaStation admin command psiadmin, an error is reported:

# psiadmin

PSC: PSC_startDaemon: connect() fails: Connection refused

Reason: the local ParaStation daemon could not be contacted. Verify that the psid(8) daemon is up and running. Check if the daemon is known to the xinetd:

# netstat -ant grep 888

tcp

0

0 *:888

*:*

LISTEN

If no "listening" socket is reported, check that the ParaStation daemon is configured within the xinet(8) configuration. Check the file /etc/xinet.d/psidstarter.

If this is ok, reload xinetd:

#kill -HUPpid of xinetd

If everything seems to be ok up to now, check for recent entries within the log file/var/log/ messages. Be aware, the log facility can be modified using the LogDestination within the config file parastation.conf. Look for lines like

Mar 24 17:19:12 pan psid[7361]: Starting ParaStation DAEMON

Mar 24 17:19:12 pan psid[7361]: Protocol Version 329

Mar 24 17:19:12 pan psid[7361]: (c) Cluster Competence \ Center GmbH

These lines indicate a normal startup of the psid. Other messages may indicate problems found by the psid, e.g. errors within the configuration file.

If the error message

Mar 24 17:19:12 pan psid[7361]: too many nodes.

is found, verify that the number of announced nodes is equal (or greater) than the number of defined nodes. See NrOfNodes within the config file parastation.conf.

6.2. Problem: node shown as "down"

Maybe the node is currently not available (shutdown or crashed), or the network connection to this node is not available.

Try to ping this node. If ok, try to startup ParaStation. From an other node, "add" this node:

psiadmin> add nodeid