GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations
555-231-743 Issue 1
November 2000
Installing the System
74Connecting the Hospitality Adjuncts
INADS Registration
After connecting the CO trunk for INADS access, call the INADS hotline to register
the switch. For Avaya technicians in the United States, use 1-800-248-1234. For
dealers and distributors in the United States, use 1-877-295-0099. If the
installation is outside of the United States, contact your Center of Excellen ce
(COE) or your Avaya representative for information about registering the swit ch.
You will be instructed to give them the dial-up number, the customer identification
number, serial number, and other information. If there is a working fax machine at
the site, request that the INADS group send you a fax that confirms all of th e
registration information.
You will also be instructed to add some information to the maintenance-related
system parameters screen. If the customer needs a login assigned, hav e the
INADS personnel create a customer login ID when they connect to the switch.
For a CMC switch, you must also set up the modem options on Page 3 befor e a
connection can be made. See Chapter 1 of

DEFINITY ECS Installation, Upgrades

and Additions for Compact Modular Cabinets

for more information on modem
setup.
change system-parameters maintenance Page 1 of 4
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1000000000
First OSS Endpoint: Abbrev Alarm Report: y
Second OSS Endpoint: Abbrev Alarm Report: n
Alarm Origination to OSS Numbers: neither
Cleared Alarm Notification? n Suspension Threshold: 5
Restart Notification? n
Test Remote Access Port? n
CPE Alarm Activation Level: none
Customer Access to INADS Port? n
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 01 : 00 Stop Time: 06 : 00
Daily Maintenance: daily Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: no EXP-LINK Interchange: no