Installing the System

 

Setting Up the Initial Options

13

 

 

2.Before you do any administration, verify that you are using the correct translation card. For a DEFINITY ECS or ProLogix system, you will start with a blank card, and all options must be set on site. For GuestWorks and DEFINITY BCS, there is a default translation card that is already administered for Offer Category B with certain default options. Check this by using the display system-parametersoffer-optionscommand.

NOTE:

If the Offer Category is not set correctly and activated, contact the technical support group or your regional Center of Excellence (COE). The switch must be set to the correct Offer Category; the translations must be saved; and the switch must be reset before you can do any translations.

3.Set the required country options using the change system-parameterscountry-optionscommand.

4.Set the daylight savings time rules using the change daylight-savings- rules command.

5.Set the date and the time using the set time command. This includes applying the daylight savings time rules set up in Step 4.

6.If the switch has EPNs in different time zone locations, use the change location command to set the time zone offset, daylight savings rules, and numbering plan area code.

7.Set the switch maintenance parameters using the change system- parameters maintenance command. For csi systems that have a C-LAN (TN799C) circuit pack, use Page 2 of this screen to verify that the Bus Bridge Packet Interface 2 has been enabled for the C-LAN circuit pack. If it is not already assigned, enter the C-LAN circuit pack equipment location, and use the defaults for the Timeslot Port fields as shown below.

change system-parameter maintenance

Page 2 of 4

 

MAINTENANCE-RELATED SYSTEM PARAMETERS

MINIMUM MAINTENANCE THRESHOLDS ( Before Notification )

TTRs: 4

CPTRs: 1

 

Call Classifier Ports:

MMIs: 0

VCs:

 

 

TERMINATING TRUNK TRANSMISSION TEST (Extension)

Test Type 100:

Test Type 102:

Test Type 105:

ISDN MAINTENANCE

 

 

 

ISDN-PRI TEST CALL Extension:

 

ISDN BRI Service SPID:

DS1 MAINTENANCE

 

 

 

DSO Loop-Around Test Call Extension:

 

SPE OPTIONAL BOARDS

 

 

 

Packet Intf1? y

Packet Intf2? y

Bus Bridge: 03C05

Inter-Board Link Timeslots Pt0: 6 Pt1: 1 Pt2: 1

Page 29
Image 29