MAINTENANCE

Return to Section TOC

TOC

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

• Only qualified personnel should perform this mainte- nance.

Turn the input power OFF at the disconnect switch or fuse box before working on this equipment.

Do not touch electrically hot parts.

Perform periodically:

1.In extremely dusty conditions, dirt may clog the cooling air channels, causing the machine to run hot. Blow out the machine at regular intervals with low pressure air. Clean the following parts. See Figure D.1.

Main transformer and choke

SCR/diode bridge

Control PC board

Starting PC board

Electrode and work cable connections

Fan assembly

Return to Section

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

ROUTINE AND PERIODIC

MAINTENANCE

Perform the following preventative maintenance at least once every six months.

Perform the following daily:

1.Check that no combustible materials are around the machine or in the welding or cutting area.

2.Remove any debris, dust, dirt, or materials that could block cooling air flow to the machine.

3.Inspect the electrode cables for any slits or punc- tures in the cable jacket. Also check for any other condition that could affect the proper operation of the machine.

NOTE: The fan motor has sealed bearings that require no service.

• Remote control terminal strip TS1.

NOTE: Keeping remote control terminal strip TS1 clean is especially important in damp locations.