CONNECTING THE LN-8 OR LN-9 TO THE IDEALARC DC-400 (14-PIN AMPHENOL)

1.Disconnect main AC input power to the Idealarc DC-400.

2.Set the POWER toggle switch to the OFF (0) posi- tion.

3.Connect the electrode cable from the LN-8 or LN-9 to the “+” terminal of the welder. Connect the work cable to the “-” terminal of the welder. Reverse this hookup for negative polarity. See Figure C.10.

NOTE: Welding cable must be sized for the current and duty cycle of the application.

4.Connect the input cable (K595-XX) between the 14-pin amphenol on the DC-400 and the input cable plug on the LN-8 or LN-9. See Figure C.10.

5.Set the welder VOLTMETER switch to the desired polarity, either DC (-) or DC (+).

6.Set the MODE switch to a CV (constant voltage) position.

7.Adjust wire feed speed at the LN-8 or LN-9 and set the welding voltage with the WIRE FEEDER VOLTAGE CONTROL.

Place the OUTPUT CONTROL switch in the “Remote” position and the OUTPUT TERMINALS switch in the “Remote” position.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

FIGURE C.10 – IDEALARC DC-400/LN-8 OR LN-9 WITH K595-XX CABLE