ACCESSORIES
FIGURE C.8 - LN-7 WIRE FEEDER CONNECTION TO THE IDEALARC DC-400
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
CONNECTING THE LN-7 TO THE IDEALARC DC-400 (TERMINAL STRIP)
1.Disconnect main AC input power to the Idealarc
2.Set the Idealarc
3.Connect the wire feeder control cable leads to the Idealarc
4.Connect the wire feeder control cable ground lead
to the frame terminal marked .
NOTE: The Idealarc
5.PERFORM THIS STEP ONLY IF THE
Extend wire feeder control cable lead #21 so it can be connected directly to the work piece.
a.Make a bolted connection using AWG #14 or larger insulated wire. Tape the bolted connec- tion with insulating tape.
NOTE: If the work cable length is less than 25 feet and the connections to the work piece are secure, then wire feeder control cable lead #21 can be connected directly to the DC- 400 terminal strip.
b.An
c.Keep the #21 lead electrically separate from the work cable circuit and connection.
d.Tape the #21 lead to work cable for ease of use.
NOTE: The connection diagram shown in Figure C.8 shows the electrode connected for positive polarity. To change polarity:
a.Set the IDEALARC
b.Move the electrode cable to the negative
c.Move the work cable to the positive (+) output terminal.
d.Set the VOLTMETER toggle switch to nega- tive
IDEALARC
LINCOLN ®