TOC

TOC

A-3

A-3

 

INSTALLATION

 

Read this entire installation section before you

LIFTING

 

start installation.

 

Return to Section

Return to Section TOC

TOC

Return to Master

Return to Master TOC

TOC

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts or electrodes with your skin or wet clothing.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

Only qualified personnel should install, use, or ser- vice this equipment.

SELECT SUITABLE LOCATION

Place the Idealarc DC-400 where clean, cooling air can flow freely in through the front louvers and out through the rear louvers. Keep dust, dirt, and other foreign materials that can be drawn into the machine to a min- imum. Failure to observe these precautions can lead to excessive operating temperatures and nuisance shut-downs.

WARNING

FALLING EQUIPMENT can cause injury.

Do not lift this machine using the lift bail if it is equipped with a heavy accessory such as a trailer or a gas cylinder.

Lift only with equipment of adequate lifting capacity.

Be sure the machine is stable when lifting.

Do not stack more than three high.

Do not stack the DC-400 on top of any other machine.

The Idealarc DC-400 weighs 473 pounds (215 kilo- grams). A permanent lift bail is located at the top of the machine, positioned at the center of gravity for sta- ble lifting.

TILTING

Place the machine on a secure, level surface. Any sur- faces you place it on other than the ground must be firm, non-skid, and structurally sound.

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

STACKING

Idealarc DC-400s may be stacked three high. The bottom machine must be on a stable, hard, level sur- face capable of supporting the weight of up to three machines (1419 pounds/645 kilograms). Be sure that the two pins in the roof of the bottom machine fit into the holes in the base of the machine above. The lift bail is positioned so that it fits without interference under the base of the second machine.

IDEALARC DC-400

LINCOLN ®

ELECTRIC

Page 9
Image 9
Lincoln Electric SVM 122-A service manual Safety Precautions, Select Suitable Location, Lifting, Tilting, Stacking