F-10

 

F-10

TROUBLESHOOTING & REPAIR

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

FUNCTION PROBLEMS

 

The machine will not shut off when

1. Make sure the three-phase

1. Check the Input Power switch

the power switch is put in the OFF

input lines are connected cor-

(S1) and the associated leads.

position.

rectly to the DC-400.

See Wiring Diagram.

 

 

2. Perform the Input Contactor

 

 

Test.

 

 

 

The Arc Control switch (S5) has no

1. Make sure the correct process

1. Check the Arc Control switch

effect in CV (FCAW/GMAW) mode

and gas are being used.

(S5) for proper operation.

when welding with the short circuit

 

2. Check the welding Mode switch

transfer process.

 

 

(S4), the microswitches, and the

 

 

 

 

associated wiring.

 

 

3. Check to make sure the output

 

 

choke control coil is not “open”

 

 

or grounded. See Wiring

 

 

Diagram.

 

 

4. Check resistor R1. Normal

 

 

resistance is 15 ohms.

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.