F-61

F-61

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR

If you repair or replace any electrical components.

INPUT IDLE AMPS AND WATTS

Input volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

200/3/60

10.9

1.2

208/3/60

10.5

1.2

220/3/60

9.9

1.2

230/3/60

9.5

1.2

380/3/60

5.8

1.2

400/3/60

5.5

1.2

415/3/60

5.3

1.2

440/3/60

5.0

1.2

460/3/60

4.8

1.2

500/3/60

4.4

1.2

575/3/60

3.8

1.2

200/3/50

19.8

1.3

220/3/50

18.0

1.3

230/3/50

17.2

1.3

380/3/50

10.4

1.3

400/3/50

9.9

1.3

415/3/50

9.5

1.3

440/3/50

9.0

1.3

500/3/50

7.9

1.3

 

 

 

OPEN CIRCUIT VOLTAGES

 

Mode

Input Hertz

Open Circuit Volts

 

Constant Current

60

54/58

 

 

Constant Current

50

51/55

 

 

Constant Voltage

60

42.5/46.5

 

 

(FCAW/GMAW)

50

42.5/46.5

 

 

Constant Voltage

60

43.5/47.5

 

 

(SUB ARC)

50

43.5/47.5

 

 

Auxiliary Output (#31-#32)

60

114/124

 

 

Auxiliary Output (#31-#32)

50

109/119

 

 

Auxiliary Output (#41-#42)

60

43.8/47.5

 

 

Auxiliary Output (#41-#42)

50

42.0/45.6

 

 

 

 

 

 