A-2

A-2

INSTALLATION

TECHNICAL SPECIFICATIONS - IDEALARC DC-400

INPUT - THREE PHASE ONLY

 

 

Standard Voltage

 

Input Current @ Rated Output

 

 

 

 

208V

 

 

 

 

87A

 

 

 

 

 

 

 

230V

 

 

 

 

78A

 

 

 

 

 

 

 

460V

 

 

 

 

39A

 

 

 

 

 

 

 

575V

 

 

 

 

32A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

Duty Cycle

 

 

Amps

 

 

Volts at Rated Amps

100%

 

 

 

 

400

 

 

 

 

 

36

 

60%

 

 

 

 

450

 

 

 

 

 

38

 

50%

 

 

 

 

500

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

Current

 

Maximum Open

 

 

 

 

Mode

 

 

Range

 

Circuit Voltage

 

Auxiliary Power

 

Constant Current

60 to 500 Amps

 

 

57 VDC

 

115 VAC, 10 Amps

 

Constant Voltage

60 to 500 Amps

 

 

45.5 VDC

 

42 VAC, 10 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED

INPUT WIRE

AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

Input Wire Size

 

Ground Wire Size

 

Input Voltage /

 

Fuse

 

Input Ampere

 

Type 75°C

 

Type 75°C

 

Frequency

(Super Lag)

 

Rating on

 

Copper Wire in

 

Copper Ground

 

 

or Breaker Size

 

Nameplate

 

Conduit AWG

 

Wire in Conduit

 

Volts/Hz

 

 

 

 

 

 

 

(IEC) Sizes

 

AWG (IEC) Sizes

 

208/60

125

 

87

 

 

4 (21 mm2)

 

6 (13 mm2)

230/60

125

 

78

 

 

4 (21 mm2)

 

6 (13 mm2)

460/60

60

 

39

 

 

8 (8.4 mm2)

 

10 (5.3 mm2)

220/50/60

125

 

81

 

 

4 (21 mm2)

 

6 (13 mm2)

230/50/60

125

 

77

 

 

4 (21 mm2)

 

6 (13 mm2)

380/50/60

70

 

47

 

 

8 (8.4 mm2)

 

8 (8.4 mm2)

400/50/60

70

 

44

 

 

8 (8.4 mm2)

 

8 (8.4 mm2)

440/50/60

60

 

41

 

 

8 (8.4 mm2)

 

10 (5.3 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL

DIMENSIONS

 

 

 

 

 

Height

 

 

Width

 

 

 

Depth

 

 

Weight

 

30.75 in.

 

 

22.25 in.

 

 

 

32 in.

 

 

473 lbs.

 

(781 mm)

 

 

(565 mm)

 

 

(813 mm)

 

 

(215 kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 