Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

F-27

F-27

TROUBLESHOOTING & REPAIR

STATIC SCR/DIODE RECTIFIER BRIDGE TEST (continued)

FIGURE F.9 – CONTROL BOARD AND SNUBBER BOARD PLUG LOCATIONS

Plug P5

Plug P1

DC-400 CONTROL

 

G2588-X

M15370-X SNUBBER

Plug P3

TEST PROCEDURE

Section TOC

Master TOC

1.Disconnect the main input supply power to the machine.

2.With the 5/16” nut driver, remove the case top and sides.

3.Disconnect the welding cables from the welding output terminals.

4.Locate and remove molex plugs P1 and P3 from the control board. See Figure F.9.

5.Locate and remove molex plug P5 from the snubber board. See Figure F.9.

6.Rotate the mode switch (S4) to the constant current (CC) position.

7.Locate and remove lead #204 from resistor R2 (40 ohms, 50 Watts). See Figure F.10.

Return to

Return to Section TOC

Return to

Return to Master TOC

FIGURE F.10 – RESISTOR R2 LOCATION

IDEALARC DC-400

LINCOLN ®

ELECTRIC

Page 71
Image 71
Lincoln Electric SVM 122-A service manual Static SCR/DIODE Rectifier Bridge Test