F-5

F-5

 

TROUBLESHOOTING & REPAIR

 

TROUBLESHOOTING GUIDE

Observe Safety Guidelines

 

 

detailed in the beginning of this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

OUTPUT PROBLEMS

 

 

The machine is dead – no output –

1. Check the three-phase input

1. Perform the Input Contactor

no fan – the pilot light is lit.

voltage at the machine. Input

Test.

 

 

voltage must match the rating

2. Check the associated leads, for

 

plate and the reconnect panel.

 

loose or

faulty connections,

 

 

 

2. Check for blown or missing

between

the input contactor

 

fuses in the input lines.

(CR1), the reconnect panel and

 

 

the main

transformer. See

 

 

Wiring Diagram.

 

 

3. Perform the Main Transformer

 

 

Test.

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

IDEALARC DC-400

LINCOLN ®

ELECTRIC

Page 49
Image 49
Lincoln Electric SVM 122-A service manual Perform the Main Transformer