F-13

 

TROUBLESHOOTING & REPAIR

 

 

F-13

 

 

 

 

 

 

 

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELDING PROBLEMS

 

 

 

 

 

 

Poor arc

characteristics

when

1. Make sure the correct weld pro-

1. Check

reed

switch CR3 for

 

welding in

the constant

voltage

cedures are being used.

 

proper

operation.

Switch

 

(CV) mode.

 

 

(Electrode, Gas, Etc.)

 

should be normally open until

 

 

 

 

2. Check the welding cables for

 

weld current is established.

 

 

 

 

 

 

 

 

 

 

 

 

 

loose or faulty connections.

2.

Remove plug P6 from the start

 

 

 

 

 

 

board. If problem is resolved,

 

 

 

 

 

 

the start board may be faulty.

 

 

 

 

 

 

Replace. See Wiring Diagram.

 

 

 

 

 

3.

Check

the

welding

Mode

 

 

 

 

 

 

switch (S4), the microswitches,

 

 

 

 

 

 

and the associated wiring.

 

 

 

 

 

4. Check

the

output capacitors

 

 

 

 

 

 

and connections. A capacitor

 

 

 

 

 

 

failure is indicated if the small

 

 

 

 

 

 

vent plug on top of a capacitor

 

 

 

 

 

 

is raised or blown out.

 

 

 

 

 

 

 

WARNING: The liquid elec-

 

 

 

 

 

 

trolyte in these capacitors is

 

 

 

 

 

 

toxic. Avoid contact with any

 

 

 

 

 

 

portion of your body. Clean

 

 

 

 

 

 

up vented

electrolyte

using

 

 

 

 

 

 

rubber gloves and a water

 

 

 

 

 

 

damped cloth. Any elec-

 

 

 

 

 

 

trolyte which gets on skin,

 

 

 

 

 

 

clean with soap and water.

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

IDEALARC DC-400

LINCOLN ®

ELECTRIC

Page 57
Image 57
Lincoln Electric SVM 122-A Trolyte in these capacitors is, Toxic. Avoid contact with any, Portion of your body. Clean