ABNORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

CONSTANT VOLTAGE SUBARC

ONE OUTPUT SCR NOT FUNCTIONING

CH1

0 volts

20 volts

5 ms

This is NOT the typical DC output voltage waveform. One output SCR is not functioning. Note the “gap” in the waveform. One SCR gate is dis- connected to simulate an open or non-functioning output SCR. Each vertical division represents 20 volts and each horizontal division repre- sents 5 milliseconds in time.

Note: Scope probes connected at

machine output terminals: (+) probe to positive terminal, (-) probe to neg- ative terminal.

SCOPE SETTINGS

Volts/Div

20V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 