OPTIONS/ACCESSORIES

FACTORYINSTALLED OPTION

DIODE OPTION
This factory installed option allows use of the cold-
start and cold electrode sensing features of the NA-3,
NA-5, or NA-5R automatic wire feeders. See the topic,
Connecting the NA-3 [NA-5] to the Idealarc DC-400
in this section of the manual.

FIELD INSTALLED OPTIONS

The following options/accessories are available for
your Idealarc DC-400 from your local Lincoln
Distributor.
COVER FOR 14-PIN AMPHENOL (LINCOLN
ELECTRIC PART NUMBER S17062-3)
Protects the amphenol from dirt and moisture when
the amphenol is not being used.
MULTIPROCESS SWITCH (K804-1. ALSO
AVAILABLE AS A FACTORY INSTALLED OPTION.)
Required when using the DC-400 for both automat-
ic/semiautomatic and stick/air carbon arc. This field or
factory installed kit mounts on the front of the DC-400.
It includes hinged covers over its output studs.
The switch has three positions.
• Wire Feeder Positive
• Wire Feeder Negative
• Stick/Air Carbon Arc
The Multiprocess Switch gives you the ability to:
Switch between “Stick Welding/Air-Carbon Arc
Cutting” or “Positive Wire Feeder” or “Negative Wire
Feeder.”
Change the polarity of a semi-automatic or auto-
matic wire feeder without changing any electrical
cable connections. See Figure C.1.
The Multiprocess Switch has two sets of output termi-
nals. You connect the wire feeder unit cables to the
set of terminals on the left side of the box (facing the
front of the machine) and the stick or air/carbon arc
cables to the set of terminals on the right side as
shown in Figure C.1.
When the Multiprocess Switch is in the “Stick Welding/
Air-Carbon Arc” position, only those terminals are
energized. The wire feeder nozzle or gun and elec-
trode are not electrically “hot” when in this mode.
Refer to installation instructions (M17137) included
with Multiprocess Kit for installation.
ACCESSORIES
C-2 C-2
LINCOLN ®
ELECTRIC
IDEALARC DC-400
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
FIGURE C.1
MULTIPROCESS SWITCH