Okidata Model ML321T Journal/PMS Log
Printer Options
Using the serial interface card (comcode 406940577), option the printer as follows for a journal or PMS log printer:
1.Press SHIFT + SEL to enter the Menu Mode.
2.Press Print (Park) to print out the Groups and Items. The first Group/Item to come up will be Printer Control/Emulation Control.
3.Press SET to option the emulation to ML.
4.Press GROUP (LF) repeatedly until you come to Serial I/F.
5.Press ITEM to advance to the next item in this group (Serial I/F) or SET to change it.
6.After changing defaults of an item, press ITEM to advance to the next one. Set the Serial I/F options for the printer as shown in Table 7.
Table 7. Okidata Model ML321T Journal/PMS Log Printer Options
Item | Setting |
|
|
Parity | None |
|
|
Serial Data 7/8 Bits | 8 (if data module) |
| 7 (if DCE port) |
|
|
Protocol | |
|
|
Diagnostic Test | No |
|
|
Busy Line | DTR |
|
|
Baud Rate | 9600 (match speed of data |
| module or DCE port) |
|
|
DSR Signal | Invalid |
|
|
DTR Signal | Ready on Power UP |
|
|
Busy Time | 200 ms |
|
|
7.After setting the options, press SHIFT + SEL to save the settings.