GuestWorks and DEFINITY ECS Release 9

Issue 1

Technician Handbook for Hospitality Installations 555-231-743

November 2000

Installing the System

 

Connecting the Hospitality Adjuncts

66

 

 

Okidata Model ML321T Journal/PMS Log

Printer Options

Using the serial interface card (comcode 406940577), option the printer as follows for a journal or PMS log printer:

1.Press SHIFT + SEL to enter the Menu Mode.

2.Press Print (Park) to print out the Groups and Items. The first Group/Item to come up will be Printer Control/Emulation Control.

3.Press SET to option the emulation to ML.

4.Press GROUP (LF) repeatedly until you come to Serial I/F.

5.Press ITEM to advance to the next item in this group (Serial I/F) or SET to change it.

6.After changing defaults of an item, press ITEM to advance to the next one. Set the Serial I/F options for the printer as shown in Table 7.

Table 7. Okidata Model ML321T Journal/PMS Log Printer Options

Item

Setting

 

 

Parity

None

 

 

Serial Data 7/8 Bits

8 (if data module)

 

7 (if DCE port)

 

 

Protocol

X-ON/X-OFF

 

 

Diagnostic Test

No

 

 

Busy Line

DTR

 

 

Baud Rate

9600 (match speed of data

 

module or DCE port)

 

 

DSR Signal

Invalid

 

 

DTR Signal

Ready on Power UP

 

 

Busy Time

200 ms

 

 

7.After setting the options, press SHIFT + SEL to save the settings.