GuestWorks and DEFINITY ECS Release 9 | Issue 1 |
Technician Handbook for Hospitality Installations | November 2000 |
Translations and Testing |
|
176 | |
|
|
Processor Channels
Use the change
■Proc Chan — Use channel 59. It is recommended that this should match the Session Local field used for this link.
■Enable — Enter y.
■Appl — Enter audix.
■Gtwy To — Not used.
■Mode — Not used.
■Interface Link — Enter the link number used on the data module screen.
■Interface Chan — Enter the Local Node Number as administered on the dial plan screen.
■Destination Node — Not used.
■Destination Port — Enter 0.
■Session Local — It is recommended that this should match the processor channel number used for this link. However, this value must match the Switch Port field on the INTUITY Switch/DCIU Interface Administration screen.
■ | Session Remote — This must match the AUDIX Number field on the |
| INTUITY Switch/DCIU Interface Administration screen. |
■ |
INTUITY Switch/DCIU Interface Administration screen.
change |
| Page | 4 of | 8 | |||||
|
| PROCESSOR CHANNEL ASSIGNMENT |
|
|
|
| |||
Proc |
| Gtwy | Interface | Destination | Session | Mach | |||
Chan Enable | Appl. | To | Mode Link/Chan | Node | Port | Local/Remote | ID | ||
49: |
|
|
|
|
|
|
|
|
|
50: |
|
|
|
|
|
|
|
|
|
51: |
|
|
|
|
|
|
|
|
|
52: |
|
|
|
|
|
|
|
|
|
53: |
|
|
|
|
|
|
|
|
|
54: |
|
|
|
|
|
|
|
|
|
55: |
|
|
|
|
|
|
|
|
|
56: |
|
|
|
|
|
|
|
|
|
57: |
|
|
|
|
|
|
|
|
|
58: |
|
|
|
|
|
|
|
|
|
59: y | audix |
| 1 | 1 |
| 0 | 59 | 1 | 1 |
60: |
|
|
|
|
|
|
|
|
|
Enabling the Data Module Link
You must now go back to the data module screen and enable the link. You should only enable the link for channel 01, the link that handles the messaging traffic.