Link Connectivity Administration
To administer the
■Administer the netcon data module (si systems only).
■Administer a processor data module (all systems).
Network Control (Netcon) Data Module
Use the add
add
|
| DATA MODULE |
|
| |
Data Extension: | 7891 | Name: NETCON | 01 | BCC: 2 | |
Type: | netcon | COS: | 15 | Maintenance Extension: 7995 | |
Physical Channel: | 01 | COR: | 50 |
|
|
ITC: | restricted | TN: | 1 |
|
|
ABBREVIATED DIALING
List1:
SPECIAL DIALING OPTION:
ASSIGNED MEMBER ( Station with a data extension button for this data module )
Ext Name
1:
You should assign all four netcon channels. The following table is an example of how you can administer the netcon channels:
Data | Physical | Maintenance |
Extension | Channel | Extension |
|
|
|
7891 | 01 | 7895 |
|
|
|
7892 | 02 | 7896 |
|
|
|
7893 | 03 | 7897 |
|
|
|