Using the operator panels
Short paper
Light sequence:
Secondary light sequence:
Press twice quickly to see the secondary light sequence.
Ready /
Message:
Paper length is too short to print the formatted data. This occurs when the printer does not know the loaded media size or when there is a problem feeding the media.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Primary light | Secondary light | |||||
sequence | sequence |
Solution:
•Make sure the loaded print media is large enough and paper size is set correctly in the Local Printer Setup Utility paper size menu (see Software and Documentation CD).
•Press to clear message and continue the job.
•Press to cancel print job.
Toner low
Light sequence:
Secondary light sequence:
Press twice quickly to see the secondary light sequence.
Ready /
Message:
Printer is ready to receive and process data. In addition, toner in the toner cartridge is getting low.
Solution:
Primary light | Secondary light |
sequence | sequence |
•Press to clear message and continue processing job.
•Remove the toner cartridge. Gently shake the toner cartridge from side to side and front to back several times to redistribute the toner, and reinsert it. Repeat this procedure multiple times. If the print remains faded, replace the toner cartridge. See Changing the toner cartridge on page 68 for help.
Overview of the Lexmark E120 operator panel
23