Fluke 43B user manual Volts / Amps / Hertz, Power, Harmonics

Page 14

Fluke 43B

Users Manual

Volts / Amps / Hertz

This function simultaneously shows the voltage and current signal. Also the Crest factor is shown. Use this function to get a first impression of the voltage and current signal before examining the signal in more detail with the other functions.

With the ENTER key you can toggle between Volts / Amps / Hertz, Power, and Harmonics functions.

Power

This function measures and displays the following power readings: active power (W), apparent power (VA), reactive power (VAR), power factor (PF), displacement power factor (DPF or cos ϕ ) and frequency. The voltage and current waveforms give a visual representation of the phase shifts

Fluke 43B can perform power measurements on balanced 3-phase, 3- conductor power systems. The load must be well balanced and have either a wye or delta configuration. This makes it possible to measure 3 phase power using single phase connections. The 3 phase power mode measures the fundamental power only.

With the ENTER key you can toggle between Power, Harmonics, and Volts / Amps / Hertz functions.

Harmonics

Harmonics are periodic distortions of the voltage, current, or power sine wave. The signal can be conceived of as a combination of various sine waves with different frequencies. The contribution of

each of these components to the full signal is shown as a bar.

The large numbers refer to the full signal; the small numbers belong to the selected harmonic component.

With the ENTER key you can toggle between Harmonics, Volts / Amps / Hertz, and Power functions.

10

Image 14
Contents Fluke 43B Placing Orders and Getting Assistance Table of Contents Index Carrying Case Contents UnpackingSafety Information Read First Safety Information Read First Fault protection. This is denoted by the symbol Current ProbePowering the Fluke 43B Powering the Fluke 43BOpening Screen Inputs Measurement ConnectionsMain Menu Introducing the Fluke 43B Main Menu Harmonics PowerVolts / Amps / Hertz Inrush Current Sags & SwellsTransients Time resolution in Sags & Swells and Record modes Screen with 16 minutes time scale Instrument Setup Setting the DateSetting the Time Adjusting the Contrast Selecting Probes Move to the probe settings for input Setting up the Harmonic- and Power Function Harmonics- and Power Settings Harmonics settings Power settingsSelecting a Language Using FlukeView Software Connecting a ComputerUsing a Printer Connecting a Parallel PrinterSelecting a Printer Type Resetting the Fluke 43B Resetting the Fluke 43BFluke 43B Cleaning the Current Probe Cleaning and StorageCleaning the Fluke 43B Storing the Fluke 43BBatteries Charging the BatteriesExtending Battery Operation Time Replacing the Ni-Cd Battery Pack Replacing the Battery Pack Ordering Code Ordering CodesReplaceable Parts Fluke 43B Ordering Code Applications Guide ManualsItem Cont’d Ordering Code FlukeView User Information Ordering CodeTroubleshooting Introduction Safety CharacteristicsPerformance Characteristics Environmental DataSafety Specifications Maximum input voltage Input 1Volts / Amps / Hertz Function SpecificationsPower HarmonicsInrush Current Sags & SwellsTransients Vertical Input ImpedanceHorizontal Scope readings DC, a DCDiode TemperatureOhm ContinuityMemory MiscellaneousDisplay MechanicalAccuracy Electrical SpecificationsCurrent Probe 80i-500S AltitudeElectromagnetic Compatibility EMC Environmental ConditionsHumidity Disturbance with test leads TL24 or Current Clamp 80i-500s Disturbance with test leads TL24 in scope modeElectromagnetic Immunity Statement of Conformity Declaration of ConformityManufacturer Sample testsLimited Warranty & Limitation of Liability Index Save Key. See Applications Man Ual