Fluke 43B user manual Adjusting the Contrast

Page 20

Fluke 43B

Users Manual

Adjusting the Contrast

Adjust the contrast of the screen for optimal visibility of the screen.

1

2

3

4

5

Open the main menu.

￿INSTRUMENT SETUP

￿CONTRAST

CONTRAST ￿

Adjust the contrast until both black and grey squares are clearly visible.

Accept the new contrast.

Note

You can also adjust the contrast immediately after turning on the Fluke 43B by using the up and down keys.

16

Image 20
Contents Fluke 43B Placing Orders and Getting Assistance Table of Contents Index Carrying Case Contents UnpackingSafety Information Read First Safety Information Read First Fault protection. This is denoted by the symbol Current ProbePowering the Fluke 43B Powering the Fluke 43BOpening Screen Inputs Measurement ConnectionsMain Menu Introducing the Fluke 43B Main Menu Harmonics PowerVolts / Amps / Hertz Inrush Current Sags & SwellsTransients Time resolution in Sags & Swells and Record modes Screen with 16 minutes time scale Instrument Setup Setting the DateSetting the Time Adjusting the Contrast Selecting Probes Move to the probe settings for input Setting up the Harmonic- and Power Function Harmonics- and Power Settings Harmonics settings Power settingsSelecting a Language Using FlukeView Software Connecting a ComputerUsing a Printer Connecting a Parallel PrinterSelecting a Printer Type Resetting the Fluke 43B Resetting the Fluke 43BFluke 43B Cleaning and Storage Cleaning the Fluke 43BCleaning the Current Probe Storing the Fluke 43BBatteries Charging the BatteriesExtending Battery Operation Time Replacing the Ni-Cd Battery Pack Replacing the Battery Pack Ordering Code Ordering CodesReplaceable Parts Manuals Item Cont’d Ordering CodeFluke 43B Ordering Code Applications Guide FlukeView User Information Ordering CodeTroubleshooting Safety Characteristics Performance CharacteristicsIntroduction Environmental DataSafety Specifications Maximum input voltage Input 1Function Specifications PowerVolts / Amps / Hertz HarmonicsInrush Current Sags & SwellsTransients Vertical Input ImpedanceHorizontal Scope readings DC, a DCTemperature OhmDiode ContinuityMiscellaneous DisplayMemory MechanicalElectrical Specifications Current Probe 80i-500SAccuracy AltitudeElectromagnetic Compatibility EMC Environmental ConditionsHumidity Disturbance with test leads TL24 or Current Clamp 80i-500s Disturbance with test leads TL24 in scope modeElectromagnetic Immunity Declaration of Conformity ManufacturerStatement of Conformity Sample testsLimited Warranty & Limitation of Liability Index Save Key. See Applications Man Ual