Fluke 43B user manual Ohm, Diode, Continuity, Capacitance, Temperature

Page 45

 

 

Specifications

 

 

 

Function Specifications

3

Meter

 

 

 

Ohm

 

 

 

Ranges

500.0to 5.000 M, 30.00 M

 

 

±(0.6 % + 5 counts)

Max. Measurement Current

0.5 mA

Measurement Voltage at open circuit

......................................................

< 4V

Diode

 

 

 

Accuracy

±(2 % +5 counts)

Max. Measurement Current

0.5 mA

Measurement Voltage at open circuit

.....................................................

< 4 V

Continuity

 

 

 

Beep

< 30 (± 5 )

Measurement Current

0.5 mA

Detection of shorts

> 1 ms

Capacitance

 

 

 

Ranges

50.00 nF to 500.0 F

 

 

±(2 % +10 counts)

Max. Measurement Current

0.5 mA

Temperature

 

 

 

Ranges (°C or °F)

-100.0 to +400.0 °C or -200.0 to +800.0 °F

 

 

±(0.5 % + 5 counts)

Record

 

 

 

Record times (selectable)

4 min to 8 days, endless (16 days)

Number of readings

1 or 2 simultaneously

Cursor Readings Accuracy

Reading Accuracy ±(2 pixels)

Record is available for the functions:

volts / amps / hertz

power

harmonics

ohms / continuity / capacitance

temperature

scope

41

Image 45
Contents Fluke 43B Placing Orders and Getting Assistance Table of Contents Index Unpacking Carrying Case ContentsSafety Information Read First Safety Information Read First Current Probe Fault protection. This is denoted by the symbolPowering the Fluke 43B Powering the Fluke 43BOpening Screen Measurement Connections InputsMain Menu Introducing the Fluke 43B Main Menu Power Volts / Amps / HertzHarmonics Sags & Swells TransientsInrush Current Time resolution in Sags & Swells and Record modes Screen with 16 minutes time scale Setting the Date Instrument SetupSetting the Time Adjusting the Contrast Selecting Probes Move to the probe settings for input Setting up the Harmonic- and Power Function Power settings Harmonics- and Power Settings Harmonics settingsSelecting a Language Connecting a Computer Using FlukeView SoftwareConnecting a Parallel Printer Using a PrinterSelecting a Printer Type Resetting the Fluke 43B Resetting the Fluke 43BFluke 43B Cleaning the Fluke 43B Cleaning and StorageCleaning the Current Probe Storing the Fluke 43BCharging the Batteries BatteriesExtending Battery Operation Time Replacing the Ni-Cd Battery Pack Replacing the Battery Pack Ordering Codes Replaceable PartsOrdering Code Item Cont’d Ordering Code ManualsFluke 43B Ordering Code Applications Guide FlukeView User Information Ordering CodeTroubleshooting Performance Characteristics Safety CharacteristicsIntroduction Environmental DataMaximum input voltage Input 1 Safety SpecificationsPower Function SpecificationsVolts / Amps / Hertz HarmonicsSags & Swells TransientsInrush Current Input Impedance HorizontalVertical DC, a DC Scope readingsOhm TemperatureDiode ContinuityDisplay MiscellaneousMemory MechanicalCurrent Probe 80i-500S Electrical SpecificationsAccuracy AltitudeEnvironmental Conditions HumidityElectromagnetic Compatibility EMC Disturbance with test leads TL24 in scope mode Electromagnetic ImmunityDisturbance with test leads TL24 or Current Clamp 80i-500s Manufacturer Declaration of ConformityStatement of Conformity Sample testsLimited Warranty & Limitation of Liability Index Save Key. See Applications Man Ual