Softing Linking Device –

Manual for Configuration, Installation and Maintenance

FF-CONF Configure your plant

Here you define the cycles of the auto save and the handling with Tag names. If you want to add or to change the project description you can do it here even so the project exists.

5.1.2.8 Help

The Help function gives you information in different ways. You can call it by pressing the F1 button and you get the Help-Information for the current function you are working with. You also can reach the Help function with the menu item Help.

Fig 5.1-10 The options of the Help function

5.1.3 ToolBar - Icons you can use while working

In this line 4 buttons are shown which can be used while FF-CONF is runing.

You can <Save Project>, start <Build All>, start <Download Project> and with the icon <Online> you change offline/online. If you want to activate or deactivate the toolbar click the right mouse button on any item of the main menu.

Fig 5.1-11 Activate or deactivate the ToolBar in any item of the main menu

5.1.4 Main view

Main view tabs (4) are the most important functions to build a configuration, to assign configured devices of the <Network Configuration> with the <Network Livelist>, to configure the <Function Block Application> and activate the messaging between the blocks of the different devices.

Below you find a free space (5) where you normally work after you have chosen a tab.

5.1.4.1 <Network Configuration>

The tab <Network Configuration> is always unhidden. In the Network Configuration you configure your network offline. The description of the devices must be allocated in the device type library. Therefore see chapter Managing the Device Type Library.

To work faster you can use the offered icons:

to sort the devices, to assign and to download the project.

In the upper right corner of your working space you find two icons <Toggle drag> and <Reset>. They allow you to relocate the devices shown in the working space and to reset to the standard notification. First click <Toggle drag> and then to an object of the configuration. Your mouse pointer changes to a cross and you can move the whole configuration picture across your working space.

Fig 5.1-12 The icons <Toggle drag> and <Reset>

V1.31

page 45 of 85

Image 45
Contents Softing Linking Device V1.31 Table of Contents FF-CONF Configure your plant Configuration ConfigurationSettingsTrace Log List and properties view Glossary Scope of Delivery Safety NotesIntended Use System RequirementsLED Block Meaning Overview Hardware FG-110 FFEthernet Port Power SupplyPin # Signal Description Pin MDI Signal Pinout Standard Ethernet CableModbus Modbus serial RS232 / RS485FF H1 fieldbus connection FIM-110 FF The pre-wired Installation of the FG-110 FFInstallation Overview PC IP address Configuration Linking Device IP address ConfigurationHomepage of the Linking Device FG-110 FF Linking Device FG-110 FF Internal Web ServerInformation InformationContactInformationVersion InformationManual DiagnosticsSystem DiagnosticsDiagnosticsFieldbus DiagnosticsInternet ProtocolDiagnosticsAdvancedFieldbus Statistics DiagnosticsAdvancedDiagnosticsAdvancedModbus Statistics DiagnosticsAdvancedModbus StatisticsTCP Monitor Point Pages MonitorConfigurationSettings ConfigurationSettingsGeneral Settings ConfigurationPage 1 Configure the Internet Protocol Read Current Values ConfigurationSettingsLD Settings3 Change user accounts new Passwords ConfigurationSystem MaintenanceFirmware ConfigurationSystem MaintenanceSystem Backup ConfigurationSystem MaintenanceTime ConfigurationPage OptionsPoint Pages ConfigurationPage OptionsConfigurationPage OptionsPoint Columns ConfigurationPage OptionsHome ConfigurationFieldbusBlocks ConfigurationFieldbus ConfigurationFieldbusDevicesConfigurationFieldbusH1 Parameter ConfigurationFieldbusHSE ConfigurationModbusCommunication ConfigurationModbusImport/Export 18 Import/Export of the Modbus Configuration Screen FF-CONF and general descriptions FF-CONF Configure your plantMain menu ProjectEdit Check All BuildDownload Download DeviceDownload Project Settings Tool SettingsProject Settings Help Network ConfigurationToolBar Icons you can use while working Main viewNetwork Livelist Function Block ApplicationParameter View Schedule ViewDevice Types List and properties viewBlock Types Devices Properties Filtering the contents General InformationFloating windows HSE Subnet Using the buttons of the objectsHSE Device H1 LinkStart FF-CONF Using the context menuHSE and H1 device types Managing the Device type libraryRemove a Device Type Create a New Project Project handlingDelete Project Configure PC and Subnet Network configuration2 Add an HSE Device 5 Add an H1 Link to the HSE Device Add H1 Device Field Device to an H1 Link Network Livelist Set the online statusDisplay the Network Livelist 4 Pull down the Network Livelist Page Function Block Application Devices first approach Configure the Function Block applicationChange tag names Configure parameters Change Block Tags 7 Rename blocks 8 Choose a block to see or edit parameters Page 10 Add a block type Handling Host devices Symptom Cause Recommended Actions Error handling and troubleshootingMODE.ACTUAL=OOS Returned Value ActionBus parameters relevant for H1 devices RangeParameter Description Bus parameters relevant for H1 Links Parameter Description Range/ Restriction Default valuePage Term Definitions Comment Other term GlossaryNetworking definitions Fieldbus definitionsTerm Definitions Page Marking of equipment type label Preface General Information on Explosion ProtektionGeneral requirements Commissioning, installationUse Maintenance and repairDisposal

FG-110 specifications

The Emerson FG-110 is a versatile and advanced fire and gas detection system designed for industrial applications. With increasing safety and regulatory standards in industries such as oil and gas, chemical processing, and manufacturing, the FG-110 provides a reliable solution for detecting early signs of fire and gas leaks, ensuring the protection of personnel, assets, and the environment.

One of the key features of the Emerson FG-110 is its robust detection capabilities. It is equipped with a variety of sensors for detecting different types of gases, including combustible gases, toxic gases, and oxygen levels. This multi-sensitivity approach allows for enhanced safety in environments where various hazardous substances may be present. The sensors are designed for high accuracy and fast response times, ensuring that any potential issues are detected swiftly before they escalate into more serious incidents.

The Emerson FG-110 utilizes advanced signal processing technologies. This includes sophisticated algorithms that filter out false alarms, providing operators and safety personnel with reliable notifications. The system's ability to distinguish between genuine threats and harmless environmental changes is crucial in high-stakes environments where false alarms can lead to unnecessary disruptions and safety concerns.

One of the standout characteristics of the FG-110 is its modular design, allowing for flexible configurations tailored to specific site requirements. Users can easily integrate additional sensors or modules as their needs evolve or as they expand their facility. This scalability makes it an ideal choice for both new installations and retrofitting existing systems.

In terms of communications, the Emerson FG-110 supports various protocols, enabling seamless integration with existing safety management systems and centralized control rooms. This connectivity enhances real-time monitoring and data analysis, helping safety teams make informed decisions efficiently.

Built with durability in mind, the Emerson FG-110 meets rigorous industrial standards. Its rugged casing and resistance to harsh environmental conditions ensure long-lasting performance, which is essential for operations in environments exposed to extreme temperatures, vibrations, or corrosive substances.

In summary, the Emerson FG-110 fire and gas detection system combines advanced sensor technologies, reliable performance, and modular design to deliver a comprehensive safety solution for industrial applications. With its focus on accuracy, flexibility, and integration, the FG-110 stands out as a robust tool in maintaining safety and preventing hazards in complex industrial environments.