Emerson FG-110 manual HSE Subnet, HSE Device, H1 Link, H1 Device, Tag Names

Page 52

Softing Linking Device –

Manual for Configuration, Installation and Maintenance

FF-CONF Configure your plant

5.2.2 Objects within the Network Configuration

PC

Here you are working online or offline to build your Network Configuration and commission your installation.

HSE Subnet

Ethernet component which corresponds with the Linking Device.

HSE Device

HSE Device or Linking Device. Field gateway to the H1 Links and the H1 devices.

H1 Link

The connective link between the HSE Device and the H1 Devices. It includes most of the integrative functions of the field bus network. So the H1 Link object represents the port of the linking device with the H1 VFD and the bus parameters common for every device on this link.

H1 Device

Terminal with type information, network address, PD Tag and user tag. Details are provided for each device in the properties view.

5.2.3 Tag Names

You find different tag names in FF-CONF. Nothing is prescribed for the User Tag. The string specified with these tag names is unlimited.

If you see different tag names, please take into consideration that there is a difference between user tags and FF PD tags. While user tags strings are not restricted in length and character sets, FF PD tags are subject to the restrictions of the VisibleString data type within FF-specs (32 ASCII characters).

As this might be inconvenient and if you don’t have any problems with the FF-restrictions, you can enforce similarity between these tag names by selecting <Settings><Project settings>and activate <Enforce PD tag same as User Tag>.

5.2.4 Using the buttons of the objects

Most of the objects offer the possibility to capture or to change the important data by clicking the enclosed buttons. In the List View they allow you to build parts of the Network Configuration. The current details are provided in the different chapters.

A double-click on the symbol of the objects of the Network Configuration or the Network Livelist hides the units below or shows hidden units again. So you can select the units to work with and get a better overview of this part of the installation.

page 52 of 85

V1.3

Image 52
Contents Softing Linking Device V1.31 Table of Contents Configuration ConfigurationSettings FF-CONF Configure your plantTrace Log List and properties view Glossary Safety Notes Scope of DeliveryIntended Use System RequirementsOverview Hardware FG-110 FF LED Block MeaningPower Supply Ethernet PortPin MDI Signal Pinout Standard Ethernet Cable Pin # Signal DescriptionModbus Modbus serial RS232 / RS485FIM-110 FF The pre-wired Installation of the FG-110 FF FF H1 fieldbus connectionInstallation Overview Linking Device IP address Configuration PC IP address ConfigurationLinking Device FG-110 FF Internal Web Server Homepage of the Linking Device FG-110 FFInformationContact InformationInformationVersion InformationManual Diagnostics DiagnosticsSystemDiagnosticsInternet Protocol DiagnosticsFieldbusDiagnosticsAdvanced DiagnosticsAdvancedFieldbus StatisticsDiagnosticsAdvancedModbus Statistics DiagnosticsAdvancedModbus StatisticsTCP Monitor Monitor Point PagesConfiguration ConfigurationSettings ConfigurationSettingsGeneral SettingsPage 1 Configure the Internet Protocol ConfigurationSettingsLD Settings Read Current Values3 Change user accounts new Passwords ConfigurationSystem MaintenanceFirmware ConfigurationSystem MaintenanceSystem Backup ConfigurationSystem MaintenanceTime ConfigurationPage Options ConfigurationPage OptionsPoint PagesConfigurationPage OptionsPoint Columns ConfigurationPage OptionsHome ConfigurationFieldbus ConfigurationFieldbusDevices ConfigurationFieldbusBlocksConfigurationFieldbusH1 Parameter ConfigurationFieldbusHSE ConfigurationModbusCommunication ConfigurationModbusImport/Export 18 Import/Export of the Modbus Configuration FF-CONF Configure your plant Screen FF-CONF and general descriptionsProject Main menuEdit Build Check AllDownload Device DownloadDownload Project Tool Settings SettingsProject Settings Network Configuration HelpToolBar Icons you can use while working Main viewFunction Block Application Network LivelistParameter View Schedule ViewList and properties view Device TypesBlock Types Devices Properties General Information Filtering the contentsFloating windows Using the buttons of the objects HSE SubnetHSE Device H1 LinkUsing the context menu Start FF-CONFManaging the Device type library HSE and H1 device typesRemove a Device Type Project handling Create a New ProjectDelete Project Network configuration Configure PC and Subnet2 Add an HSE Device 5 Add an H1 Link to the HSE Device Add H1 Device Field Device to an H1 Link Set the online status Network LivelistDisplay the Network Livelist 4 Pull down the Network Livelist Page Function Block Application Configure the Function Block application Devices first approachChange tag names Configure parameters Change Block Tags 7 Rename blocks 8 Choose a block to see or edit parameters Page 10 Add a block type Handling Host devices Error handling and troubleshooting Symptom Cause Recommended ActionsReturned Value Action MODE.ACTUAL=OOSRange Bus parameters relevant for H1 devicesParameter Description Parameter Description Range/ Restriction Default value Bus parameters relevant for H1 LinksPage Glossary Term Definitions Comment Other termFieldbus definitions Networking definitionsTerm Definitions Page Preface General Information on Explosion Protektion Marking of equipment type labelCommissioning, installation General requirementsMaintenance and repair UseDisposal

FG-110 specifications

The Emerson FG-110 is a versatile and advanced fire and gas detection system designed for industrial applications. With increasing safety and regulatory standards in industries such as oil and gas, chemical processing, and manufacturing, the FG-110 provides a reliable solution for detecting early signs of fire and gas leaks, ensuring the protection of personnel, assets, and the environment.

One of the key features of the Emerson FG-110 is its robust detection capabilities. It is equipped with a variety of sensors for detecting different types of gases, including combustible gases, toxic gases, and oxygen levels. This multi-sensitivity approach allows for enhanced safety in environments where various hazardous substances may be present. The sensors are designed for high accuracy and fast response times, ensuring that any potential issues are detected swiftly before they escalate into more serious incidents.

The Emerson FG-110 utilizes advanced signal processing technologies. This includes sophisticated algorithms that filter out false alarms, providing operators and safety personnel with reliable notifications. The system's ability to distinguish between genuine threats and harmless environmental changes is crucial in high-stakes environments where false alarms can lead to unnecessary disruptions and safety concerns.

One of the standout characteristics of the FG-110 is its modular design, allowing for flexible configurations tailored to specific site requirements. Users can easily integrate additional sensors or modules as their needs evolve or as they expand their facility. This scalability makes it an ideal choice for both new installations and retrofitting existing systems.

In terms of communications, the Emerson FG-110 supports various protocols, enabling seamless integration with existing safety management systems and centralized control rooms. This connectivity enhances real-time monitoring and data analysis, helping safety teams make informed decisions efficiently.

Built with durability in mind, the Emerson FG-110 meets rigorous industrial standards. Its rugged casing and resistance to harsh environmental conditions ensure long-lasting performance, which is essential for operations in environments exposed to extreme temperatures, vibrations, or corrosive substances.

In summary, the Emerson FG-110 fire and gas detection system combines advanced sensor technologies, reliable performance, and modular design to deliver a comprehensive safety solution for industrial applications. With its focus on accuracy, flexibility, and integration, the FG-110 stands out as a robust tool in maintaining safety and preventing hazards in complex industrial environments.