<Change Settings and Reboot>

When you click the button <Change Settings and Reboot> the web site shuts down and the system reboots.

The input values will be checked for consistency. If the input values are not consistent, the Linking Device will propose consistent values. You can use the proposed values by clicking <yes> or keep the values you entered by selecting <no>.

The Linking Device will be rebooted after a few seconds and the new values will be accepted.

If you change the IP address of the Linking Device, the IP connection between PC and Linking Device will be lost. You have to use the new IP address to re-establish web access to the Linking Device.

If all parameters are correct, the new values are accepted and displayed.

<Read Current Values>

If you changed some of the parameters and you are not sure of your changes, click the button <Read Current Values>. Input fields which are already filled are shown again.

i

Do not access the web server of the Linking Device before the NEW NETWORK SETTINGS or ERROR OCCURED message is displayed in the browser window. If you do so, you will have to clear the cache of your web browser after the boot process has finished, and then re- establish a connection to the web server of the Linking Device.

4.5.1.3 <Configuration><Settings><LD Settings>

Fig 4.5-2 Configuration of Linking Device Settings

Each Linking device gets a unique PD-Tag which includes the serial number.

The Webpage “LD-Settings” can be used to change the PD-Tag of the Linking device, the Link ID as well as the Node Address of the H1 links.

page 26 of 85

V1.3

Image 26
Contents Softing Linking Device V1.31 Table of Contents Configuration ConfigurationSettings FF-CONF Configure your plantTrace Log List and properties view Glossary Intended Use Safety NotesScope of Delivery System RequirementsOverview Hardware FG-110 FF LED Block MeaningPower Supply Ethernet PortModbus Pin MDI Signal Pinout Standard Ethernet CablePin # Signal Description Modbus serial RS232 / RS485FIM-110 FF The pre-wired Installation of the FG-110 FF FF H1 fieldbus connectionInstallation Overview Linking Device IP address Configuration PC IP address ConfigurationLinking Device FG-110 FF Internal Web Server Homepage of the Linking Device FG-110 FFInformationVersion InformationInformationContact InformationManual Diagnostics DiagnosticsSystemDiagnosticsInternet Protocol DiagnosticsFieldbusDiagnosticsAdvanced DiagnosticsAdvancedFieldbus StatisticsDiagnosticsAdvancedModbus Statistics DiagnosticsAdvancedModbus StatisticsTCP Monitor Monitor Point Pages Configuration ConfigurationSettings ConfigurationSettingsGeneral SettingsPage 1 Configure the Internet Protocol ConfigurationSettingsLD Settings Read Current Values3 Change user accounts new Passwords ConfigurationSystem MaintenanceFirmware ConfigurationSystem MaintenanceSystem Backup ConfigurationSystem MaintenanceTime ConfigurationPage Options ConfigurationPage OptionsPoint PagesConfigurationPage OptionsPoint Columns ConfigurationPage OptionsHome ConfigurationFieldbus ConfigurationFieldbusDevices ConfigurationFieldbusBlocksConfigurationFieldbusH1 Parameter ConfigurationFieldbusHSE ConfigurationModbusCommunication ConfigurationModbusImport/Export 18 Import/Export of the Modbus Configuration FF-CONF Configure your plant Screen FF-CONF and general descriptionsEdit Main menuProject Build Check AllDownload Project DownloadDownload Device Project Settings SettingsTool Settings ToolBar Icons you can use while working Network ConfigurationHelp Main viewParameter View Function Block ApplicationNetwork Livelist Schedule ViewList and properties view Device TypesBlock Types Devices Properties Floating windows Filtering the contentsGeneral Information HSE Device Using the buttons of the objectsHSE Subnet H1 LinkUsing the context menu Start FF-CONFManaging the Device type library HSE and H1 device typesRemove a Device Type Project handling Create a New ProjectDelete Project Network configuration Configure PC and Subnet2 Add an HSE Device 5 Add an H1 Link to the HSE Device Add H1 Device Field Device to an H1 Link Display the Network Livelist Network LivelistSet the online status 4 Pull down the Network Livelist Page Function Block Application Configure the Function Block application Devices first approachChange tag names Configure parameters Change Block Tags 7 Rename blocks 8 Choose a block to see or edit parameters Page 10 Add a block type Handling Host devices Error handling and troubleshooting Symptom Cause Recommended ActionsReturned Value Action MODE.ACTUAL=OOSParameter Description Bus parameters relevant for H1 devicesRange Parameter Description Range/ Restriction Default value Bus parameters relevant for H1 LinksPage Glossary Term Definitions Comment Other termTerm Definitions Networking definitionsFieldbus definitions Page Preface General Information on Explosion Protektion Marking of equipment type labelCommissioning, installation General requirementsMaintenance and repair UseDisposal