KEYBOARD LOCK

The Key lock function can be extended selectively to different key function controls. By default the KEYLOCK OFF shall always appear, then by ripetitively pressing the “SELECT” key you will have access to the following functions in turn:

MENU MESSAGE

FUNCTION

a) : KEYLOCK ALL

Lock ALL: All keyboard functions disabled (1)

b) : KEYLOCK CNTRL

Lock BRIGHT. +/-, CONTR. +/-, USER-STORE_Function

c) : KEYLOCK STORE

Lock USER-STORE_Function

d) : KEYLOCK OFF

No lock

 

 

 

 

GLOBAL MENU

 

 

 

 

 

3-GUNS

 

 

DEGAUSS

 

 

KEYLOCK CNTRL

 

Pressing the “EXIT” key:

the displayed lock-mode item is activated. The Special Function Menu window disappears, and a window simi- lar to the one shown below appears on all monitors, showing which kind of lock function took place. From now on, all key boards operate according to the selected Lock-mode (except from the keyboard UNLOCK function). If the ‘Daisy Chain Mode’ option is enabled, the proper daisy chain command sequence is transmitted over the Daisy Chain Line and all the other monitors connected execute the command.

Pressing “Adj. +” or “Adj. -”: the highlight selection of menu item moves downward/upward, and exit from the Lock-item line without activat- ing any LOCK mode.

If “Lock All” (or “Store” or “Cntrl”) is enabled, it is not allowed to activate OSD Menu anymore.

The warning message shall be displayed. To access OSD Menu, it is necessary to unlock the keyboard: e.g.

KEYBOARD

LOCKED CNTRL

´ABC MENU

When the Global Menu window is displayed on the screen, if ‘ABC <status>’ item is highlighted:

GLOBAL MENU

SEL EXIT - +

DEGAUSS

KEYLOCK ALL

ABC FULL

Pressing the “SELECT” key, the ABC-mode selection <status> toggles between the 3 possible choices: FULL / REDUCED / OFF.

Every time the “SELECT” key is pressed once, the newly displayed selection becames effective. If the ‘Daisy Chain Mode’ option is enabled, the proper daisy chain command sequence is transmitted over the Daisy Chain Line and all other monitors execute the same function.

ABC FULL

Set ABC-Full Range

ABC REDUCED

Set ABC-Reduced Range (the real brightness and contrast depend on the ambient light)

ABC OFF

Set ABC-Off (Disabled)

Image 21
Contents MGD203 MGD403 FCC Notice FCC Notice CopyrightCopyright CE Information and USE of the Control Panel Hardware OSDAppendix ‘ An introduction to the product features English English Agas Main FeaturesCathode RAY Tube AutoscanDDC Display Data Channel Environment1GUN / 3 Guns Brightness Show ConfigurationOrbiting Daisy Chain InterfacePower Management Reference SettingResolution Universal Power SupplyUnpacking InspectionPower LED Colour Connecting YourMonitor Nizable Circuit BreakerSUB Video H/H+V RS-232 RS232 ConnectorLED Color / Meaning Table Hardware on Screen Display Direct Keyboard Functional Interface User Interface FunctionsDirect Keying Functions ModeKeylock ALL ON-SCREEN-DISPLAY Special Keys FunctionsGlobal Menu Controls GunsDegauss Keylock Cntrl Global Menu Guns DegaussKeyboard Locked Cntrl Global Menu SEL Exit + Degauss Keylock ALLREF. Setting Power SAVLocal Menu Local Menu Controls Power SAV OFFABC Master Auto DEG OFFDaisy Addr Daisy CHInput = Orbiting OFF Light BAR OFFOSD Reverse Local Menu SEL Exit + Orbiting OFF Light BAR Show Config OSD PositionSEL Exit Size Store REF. SETShift TiltSEL Exit + ABC CT ABC ContrastABC Brightness ABC BR´ABC REDUCTION-FACTORS Combined to REF. Settings Service Menu´SERVICE Menu Local Menu SEL Exit + ABC Contrast ABC BrightnessAppendix Reliability Technical SpecificationsHorizontal Range Vertical Range+5V EXT PIN AssignmentMGD 203 Mechanical Specifications Carateristiques Mecaniques MGD 403 Mechanical Specifications Carateristiques Mecaniques How to connect a plug VGA MGD203 / MGD403 Factory Preset Video Timings