Black Box KV3108SA-R4, SW722A-R4, SW721A-R4, SW724A-R4 Operation Hardware and Keyboard Commands

Page 55

SERVSWITCH™

4.Operation: Hardware and Keyboard Commands

The first part of this chapter, Section 4.1, gives you some guidelines that you should follow to make sure your ServSwitch works properly with your equipment.

Section 4.2 summarizes the ServSwitch’s keyboard commands, and Section 4.3 describes these commands in detail.

Section 4.4 outlines how you can select ports or upgrade firmware from an optional computer or terminal connected to the ServSwitch’s RS-232 port.

IMPORTANT NOTES

If, as you prepare to operate the ServSwitch, you see a prompt on your screen asking you to “Enter password,” you must type in the unit’s access password before the ServSwitch will allow you to enter commands. See Section 5.5.2.

To start any ServSwitch keyboard command, you must press and release the left Control Key ([Ctrl]). Pressing and releasing [Ctrl] cues the Switch to expect command characters from the keyboard. You then have two seconds in which to start entering a valid command. If no command is begun within two seconds or if an invalid command is entered, the ServSwitch aborts the command.

When entering commands that contain numbers or math symbols, use only the numeral keys located at the top of your alphanumeric keyboard. Numbers and symbols entered from the numeric keypad to the right will not be recognized as valid.

4.1 Guidelines for Using the ServSwitch with Your Equipment

4.1.1 CPUS

Use only IBM PC/AT or PS/2 or 100% compatible machines. The ServSwitch does not support IBM PC/XT™ or compatible machines. It does not support machines that output CGA or EGA video. SGI machines must output the current type of SGI video on 13W3 connectors or standard VGA video on HD15 connectors.

4.1.2MOUSE AND KEYBOARD

When you power up your ServSwitch system, make sure that your CPUs, mouse (mice), and keyboard(s) are properly cabled to the Switch (or to the appropriate master or submaster unit). When you boot up your CPUs, the master(s) and/or submasters to which they are connected should already be ON. Unless it’s absolutely necessary, don’t disconnect and reconnect a mouse or keyboard from a ServSwitch while the Switch is ON; if you have to do this, issue the Reset command ([Ctrl] R—see Section 4.3.6) after you reconnect the mouse or keyboard.

32

Image 55
Contents Customer Support Information Step-By-Step Quick Install Guide for the ServSwitch Servswitch Quick Install Guide Attach your keyboard and mouse this way PS/2 equipment shown Connection sequence User-Station Connections PS/2 type user-station connections PC/AT type user-station connections RS/6000 type user-station connections SGI type user-station connections Cascade Connections Optional CPU Connections Servswitch Quick Install Guide PS/2 type CPU connections Servswitch Quick Install Guide PC/AT type CPU connections standard cable RS/6000 type CPU connections SGI type CPU connections RS-232 connection to DB9 male computer port FA042 Power Connection Page Copyright 2000. Black Box Corporation. All rights reserved SW721A-R4SW723A-R4 SW722A-R4SW724A-R4 KV3108SA-R4SW725A-R4 Welcome to the ServSwitchTM FamilyServswitch FCC/IC Statements Servswitch NOM Statement Contents Table of Contents Servswitch Appendix Standards SpecificationsSpecifications Maximum Altitude Introduction Operating FeaturesComplete Package Servswitch Front Panel Front panel of a 2 to 1 ServSwitch SW721A-R4ON/OFF CPU N Rear PanelMonitor Equipment Requirements Cable RequirementsQuick Setup Guide InstallationInstallation Procedure Connecting Cpus Connecting Submasters Optional Kernel is bad, load new kernel through serial port Chapter Cascading in ServSwitch Systems Cable Requirements for Expansion Basic ServSwitch cascading Cascading with Matrix ServSwitch submasters Kernel is bad, load new kernel through serial port Installation Guidelines for Using the ServSwitch with Your Equipment Operation Hardware and Keyboard CommandsOperation Hardware and Keyboard Commands Monitor Video Quality vs. Distance for Original Serv Cables Video Quality vs. Distance for Coaxial Cables ServSwitch’s Keyboard Commands Keyboard-Command SummaryScan OFF Commands in Detail Scan Mode Reset Send Null Byte PS/2 Type Mice only Display Label Using the RS-232 Port Switching Ports Remotely Optional Upgrading the Firmware with Terminal-Emulation Software Receive successful Hit space to program Upgrading the Firmware with the DOS Copy Command Operation Hardware and Keyboard Commands Overview Operation On-Screen DisplayOperation On-Screen Display Configure system Configure SystemChanging the mouse type Servswitch Changing the maximum number of computers Configure System Expansion Units Configure System Scan Time Typematic Rate Configure computers Configure ComputersChanging a computer’s name Changing a CPU port’s keyboard mode Changing a CPU port’s mouse type Color Scheme Configure OverlayResolution Background Color and Text Color Configure Overlay Computer Label Show Computer Number 10. The Configure security Configure SecurityNew password 11. The computer select window Computer Select WindowRestoring Factory-Default Settings TroubleshootingCommon Problems YOU CAN’T Switch Ports from the Keyboard Servswitch Scans or Switches to Empty or Nonexistent Ports Your Mouse DOESN’T Move the POINTER/CURSOR Your ON-SCREEN Display is not Synchronized Shipping and Packaging Calling Black BoxKeyboard-Command Settings Appendix a Nvram Factory DefaultsOption Default setting On-Screen Configuration SettingsAccess time Seconds 16 hours, 39 minutes Appendix B Cable Product Codes Servswitch Appendix C Pinout of RS-232 Port Key Pressed on Scan Code LK461 Keyboard Appendix D The LK461 KeyboardFigure G-1. Rackmount assembly Appendix E Rackmounting ServSwitchPage

SW725A-R4, SW722A-R4, SW723A-R4, KV3108SA-R4, SW724A-R4 specifications

The Black Box SW721A-R4, SW724A-R4, KV3108SA-R4, SW723A-R4, and SW722A-R4 are cutting-edge network switches that cater to the demanding needs of modern data environments. These models are designed to provide high performance, reliability, and advanced features suitable for both enterprise-level deployments and smaller networks.

The SW721A-R4 and SW724A-R4 are primarily layer 2 switches that support essential networking protocols such as IEEE 802.1Q for VLAN tagging, ensuring secure and efficient traffic management. With robust forwarding capabilities, these switches boast high-speed Gigabit Ethernet ports, which enable seamless data transfer and reduce latency in data-driven applications. Their fanless design also ensures quiet operation, making them ideal for office settings and noise-sensitive areas.

Another noteworthy addition is the KV3108SA-R4, a versatile KVM switch that provides remote management capabilities. This model can control multiple servers and computers from a single console, allowing IT personnel to streamline operations and reduce physical space requirements. With support for high-resolution video output and an intuitive user interface, the KV3108SA-R4 enhances usability while maintaining efficiency in server management.

The SW723A-R4 and SW722A-R4 models further enhance network capabilities with their advanced Layer 3 functions. These switches support static routing and dynamic routing protocols, making them suitable for complex networking scenarios. They are equipped with a comprehensive set of security features, including port security and access control lists (ACLs), ensuring that sensitive information is well-protected against unauthorized access.

All of these Black Box models operate on advanced technologies such as QoS (Quality of Service), which helps prioritize critical traffic and ensures optimal performance during peak usage periods. Additionally, they support Power over Ethernet (PoE), enabling the powering of network devices such as IP cameras and VoIP phones without the need for additional electrical outlets.

In summary, the Black Box SW721A-R4, SW724A-R4, KV3108SA-R4, SW723A-R4, and SW722A-R4 represent a fusion of performance, versatility, and security in network infrastructure. These switches are perfect for businesses looking to enhance their connectivity solutions, ensuring that they can meet the demands of an increasingly digital world while maintaining high standards of efficiency and reliability.