Black Box SW723A-R4, SW722A-R4, KV3108SA-R4, SW721A-R4 manual Receive successful Hit space to program

Page 70

CHAPTER 4: Operation: Hardware and Keyboard Commands

ASCII text file (not XMODEM, ZMODEM, etc.). The Switch will send back a series of ASCII period (“.”) characters (decimal 46, hex 2E) that shows the progress of the file-copying procedure. It will also flash LED 1 or 4 (depending on the data rate). Once the file transfer is complete, the Switch should light LED 2 and send the message:

Receive successful

Hit space to program

If something goes wrong during this process, you might receive any of these messages instead:

Checksum error or Record error or Data error

Receive failed

Try again Y/N?

These messages are usually caused by one of these problems:

The RS-232 cable or adapter is loose, too long, defective, or incorrectly pinned;

The terminal emulator’s setting for the serial port, data rate, data format, and/or file-transfer protocol is wrong; or

Either the PC’s serial port or the Switch’s RS-232 port is defective.

To try again, press “Y” on the PC’s keyboard; the ServSwitch goes back to step 1 and sends “Waiting for file...”. To abort, press “N” on the PC’s keyboard; the Switch skips ahead to the “Hit enter to boot” message shown in step 5, but the firmware will remain unchanged. If the trouble recurs and you can’t pinpoint it, call Black Box for technical support.

5.If the file transfer is successful, press the space bar on the PC’s keyboard. LED 2 will go dark briefly while the ServSwitch begins reprogramming its flash memory with the new firmware. It should send the message:

Programming flash

This will be followed by another series of ASCII periods that shows the progress of the flash-reprogramming procedure. If this phase is successfully completed, the Switch will begin verifying the new firmware; it will send the message:

Verifying flash

This will be followed by a third series of progress-indicating ASCII periods. If verification is successful, the Switch will light LED 3 and send the message:

Verify successful

Hit enter to boot

If you get an error message at any time during the programming or verifying phase, call Black Box for technical support.

47

Image 70
Contents Customer Support Information Step-By-Step Quick Install Guide for the ServSwitch Servswitch Quick Install Guide Attach your keyboard and mouse this way PS/2 equipment shown Connection sequence User-Station Connections PS/2 type user-station connections PC/AT type user-station connections RS/6000 type user-station connections SGI type user-station connections Cascade Connections Optional CPU Connections Servswitch Quick Install Guide PS/2 type CPU connections Servswitch Quick Install Guide PC/AT type CPU connections standard cable RS/6000 type CPU connections SGI type CPU connections RS-232 connection to DB9 male computer port FA042 Power Connection Page Copyright 2000. Black Box Corporation. All rights reserved Welcome to the ServSwitchTM Family SW721A-R4SW723A-R4 SW722A-R4SW724A-R4 KV3108SA-R4SW725A-R4Servswitch FCC/IC Statements Servswitch NOM Statement Contents Table of Contents Servswitch Appendix Specifications StandardsSpecifications Maximum Altitude Introduction Operating FeaturesComplete Package Servswitch Front panel of a 2 to 1 ServSwitch SW721A-R4 Front PanelON/OFF Rear Panel CPU NMonitor Cable Requirements Equipment RequirementsInstallation Quick Setup GuideInstallation Procedure Connecting Cpus Connecting Submasters Optional Kernel is bad, load new kernel through serial port Chapter Cascading in ServSwitch Systems Cable Requirements for Expansion Basic ServSwitch cascading Cascading with Matrix ServSwitch submasters Kernel is bad, load new kernel through serial port Installation Operation Hardware and Keyboard Commands Guidelines for Using the ServSwitch with Your EquipmentOperation Hardware and Keyboard Commands Monitor Video Quality vs. Distance for Original Serv Cables Video Quality vs. Distance for Coaxial Cables Keyboard-Command Summary ServSwitch’s Keyboard CommandsScan OFF Commands in Detail Scan Mode Reset Send Null Byte PS/2 Type Mice only Display Label Using the RS-232 Port Switching Ports Remotely Optional Upgrading the Firmware with Terminal-Emulation Software Receive successful Hit space to program Upgrading the Firmware with the DOS Copy Command Operation Hardware and Keyboard Commands Operation On-Screen Display OverviewOperation On-Screen Display Configure System Configure systemChanging the mouse type Servswitch Changing the maximum number of computers Configure System Expansion Units Configure System Scan Time Typematic Rate Configure Computers Configure computersChanging a computer’s name Changing a CPU port’s keyboard mode Changing a CPU port’s mouse type Configure Overlay Color SchemeResolution Background Color and Text Color Configure Overlay Computer Label Show Computer Number Configure Security 10. The Configure securityNew password Computer Select Window 11. The computer select windowTroubleshooting Restoring Factory-Default SettingsCommon Problems YOU CAN’T Switch Ports from the Keyboard Servswitch Scans or Switches to Empty or Nonexistent Ports Your Mouse DOESN’T Move the POINTER/CURSOR Your ON-SCREEN Display is not Synchronized Calling Black Box Shipping and PackagingAppendix a Nvram Factory Defaults Keyboard-Command SettingsOn-Screen Configuration Settings Option Default settingAccess time Seconds 16 hours, 39 minutes Appendix B Cable Product Codes Servswitch Appendix C Pinout of RS-232 Port Appendix D The LK461 Keyboard Key Pressed on Scan Code LK461 KeyboardAppendix E Rackmounting ServSwitch Figure G-1. Rackmount assemblyPage

SW725A-R4, SW722A-R4, SW723A-R4, KV3108SA-R4, SW724A-R4 specifications

The Black Box SW721A-R4, SW724A-R4, KV3108SA-R4, SW723A-R4, and SW722A-R4 are cutting-edge network switches that cater to the demanding needs of modern data environments. These models are designed to provide high performance, reliability, and advanced features suitable for both enterprise-level deployments and smaller networks.

The SW721A-R4 and SW724A-R4 are primarily layer 2 switches that support essential networking protocols such as IEEE 802.1Q for VLAN tagging, ensuring secure and efficient traffic management. With robust forwarding capabilities, these switches boast high-speed Gigabit Ethernet ports, which enable seamless data transfer and reduce latency in data-driven applications. Their fanless design also ensures quiet operation, making them ideal for office settings and noise-sensitive areas.

Another noteworthy addition is the KV3108SA-R4, a versatile KVM switch that provides remote management capabilities. This model can control multiple servers and computers from a single console, allowing IT personnel to streamline operations and reduce physical space requirements. With support for high-resolution video output and an intuitive user interface, the KV3108SA-R4 enhances usability while maintaining efficiency in server management.

The SW723A-R4 and SW722A-R4 models further enhance network capabilities with their advanced Layer 3 functions. These switches support static routing and dynamic routing protocols, making them suitable for complex networking scenarios. They are equipped with a comprehensive set of security features, including port security and access control lists (ACLs), ensuring that sensitive information is well-protected against unauthorized access.

All of these Black Box models operate on advanced technologies such as QoS (Quality of Service), which helps prioritize critical traffic and ensures optimal performance during peak usage periods. Additionally, they support Power over Ethernet (PoE), enabling the powering of network devices such as IP cameras and VoIP phones without the need for additional electrical outlets.

In summary, the Black Box SW721A-R4, SW724A-R4, KV3108SA-R4, SW723A-R4, and SW722A-R4 represent a fusion of performance, versatility, and security in network infrastructure. These switches are perfect for businesses looking to enhance their connectivity solutions, ensuring that they can meet the demands of an increasingly digital world while maintaining high standards of efficiency and reliability.