Black Box SW591C, SW590A-R2 manual For, Self-Test Function, Sending or Suppressing Breaks

Page 15

CHAPTER 3: Installation

ARMING CHARACTER SWITCH POSITIONS

 

 

 

 

 

 

 

 

 

 

 

LSB

 

 

 

 

 

 

MSB

ASCII CTRL

HEX

DECIMAL

1

2

3

4

5

6

7

8

 

DF

223

ON

ON

ON

ON

ON

OFF

ON

ON

 

E0

224

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

 

E1

225

ON

OFF

OFF

OFF

OFF

ON

ON

ON

 

E2

226

OFF

ON

OFF

OFF

OFF

ON

ON

ON

 

E3

227

ON

ON

OFF

OFF

OFF

ON

ON

ON

 

E4

228

OFF

OFF

ON

OFF

OFF

ON

ON

ON

 

E5

229

ON

OFF

ON

OFF

OFF

ON

ON

ON

 

E6

230

OFF

ON

ON

OFF

OFF

ON

ON

ON

 

E7

231

ON

ON

ON

OFF

OFF

ON

ON

ON

 

E8

232

OFF

OFF

OFF

ON

OFF

ON

ON

ON

 

E9

233

ON

OFF

OFF

ON

OFF

ON

ON

ON

 

EA

234

OFF

ON

OFF

ON

OFF

ON

ON

ON

 

EB

235

ON

ON

OFF

ON

OFF

ON

ON

ON

 

EC

236

OFF

OFF

ON

ON

OFF

ON

ON

ON

 

ED

237

ON

OFF

ON

ON

OFF

ON

ON

ON

 

EE

238

OFF

ON

ON

ON

OFF

ON

ON

ON

 

EF

239

ON

ON

ON

ON

OFF

ON

ON

ON

 

F0

240

OFF

OFF

OFF

OFF

ON

ON

ON

ON

 

F1

241

ON

OFF

OFF

OFF

ON

ON

ON

ON

 

F2

242

OFF

ON

OFF

OFF

ON

ON

ON

ON

 

F3

243

ON

ON

OFF

OFF

ON

ON

ON

ON

 

F4

244

OFF

OFF

ON

OFF

ON

ON

ON

ON

 

F5

245

ON

OFF

ON

OFF

ON

ON

ON

ON

 

F6

246

OFF

ON

ON

OFF

ON

ON

ON

ON

 

F7

247

ON

ON

ON

OFF

ON

ON

ON

ON

 

F8

248

OFF

OFF

OFF

ON

ON

ON

ON

ON

 

F9

249

ON

OFF

OFF

ON

ON

ON

ON

ON

 

FA

250

OFF

ON

OFF

ON

ON

ON

ON

ON

 

FB

251

ON

ON

OFF

ON

ON

ON

ON

ON

 

FC

252

OFF

OFF

ON

ON

ON

ON

ON

ON

 

FD

253

ON

OFF

ON

ON

ON

ON

ON

ON

 

FE

254

OFF

ON

ON

ON

ON

ON

ON

ON

 

FF

255

ON

ON

ON

ON

ON

ON

ON

ON

3.7Setting Global Characteristics with the Individual Banks

Several other system-wide options are specified not by the system switch banks, but rather by the eighth switch position of the individual port switch banks. Explanations and tables are given below.

Self-Test Function

NOTE

The COS II can perform a number of self-tests that check the memory, the LEDS, the DIP switches, the ports, and the interrupt circuitry of the Switch.

More information about the self-tests is given in Section 4.8.

For

Set SWA 8

Normal operation

OFF

Self-test

ON

Sending or Suppressing Breaks

We recommend that you run software flow control from your application during self-test.

You can set the COS II either to pass break characters along or to block them from reaching your devices. SWB 8 controls this function.

15

Image 15
Contents Code Operated Switch II 4-Port Expansion Board Code Operated Switch Contents Memory 8K buffer Enclosure Steel SpecificationsIntroduction Installation Setting the DIP switchesIntroduction Installation Functions and Arrangement of the Switch BanksBank Assignments Configuring Ports with the Individual Port Switch BanksTo Set a Pause Timeout SettingTo Set This Mode Set SWFLSB MSB Ascii LSB MSB Ascii Ctrl HEX LSB 128 174 For Self-Test FunctionSending or Suppressing Breaks DTE Port DCE Port Configuring Ports for DTE or DCESignal direction Master Slave Leads passedConnecting and Powering Up the COS-II Operation Signaling a LockText Mode Graphics ModeIndicators Front-Panel ButtonSelf-Tests Serial Port Test Interrupt TestAll Tests Individual Port Switch Bank Settings Settings for Switch Option FQuick Reference Guide System Switch Options Available through Position Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax